565
:TRIGger:LIN:TRIGger
Command Syntax
:TRIGger:LIN:TRIGger <condition>
<condition> ::= {SYNCbreak | ID | DATA}
The :TRIGger:LIN:TRIGger command sets the LIN trigger condition to be:
•
SYNCbreak — Sync Break.
•
ID — Frame ID.
Use the :TRIGger:LIN:ID command to specify the frame ID.
•
DATA — Frame ID and Data.
Use the :TRIGger:LIN:ID command to specify the frame ID.
Use the :TRIGger:LIN:PATTern:DATA:LENGth and
:TRIGger:LIN:PATTern:DATA commands to specify the data string length
and value.
Query Syntax
:TRIGger:LIN:TRIGger?
The :TRIGger:LIN:TRIGger? query returns the current LIN trigger value.
Return Format
<condition><NL>
<condition> ::= {SYNC | ID | DATA}
Errors
•
See Also
•
"Introduction to :TRIGger Commands"
•
•
•
":TRIGger:LIN:PATTern:DATA:LENGth"
•
•
":TRIGger:LIN:SIGNal:DEFinition"
•
N O T E
The ID and DATA options are available when the automotive CAN and LIN serial decode
option (Option AMS) has been licensed.