:MEASure:COUNter
Command Syntax
:MEASure:COUNter [<source>]
<source> ::= {<digital channels> | CHANnel<n> | EXTernal}
<digital channels> ::= DIGital0,..,DIGital15 for the MSO models
<n> ::= {1 | 2 | 3 | 4} for the four channel oscilloscope models
<n> ::= {1 | 2} for the two channel oscilloscope models
The :MEASure:COUNter command installs a screen measurement and
starts a counter measurement. If the optional source parameter is
specified, the current source is modified. Any channel except Math may be
selected for the source.
The counter measurement counts trigger level crossings at the selected
trigger slope and displays the results in Hz. The gate time for the
measurement is automatically adjusted to be 100 ms or twice the current
time window, whichever is longer, up to 1 second. The counter
measurement can measure frequencies up to 125 MHz. The minimum
frequency supported is 1/(2 X gate time).
The Y cursor shows the the edge threshold level used in the measurement.
Only one counter measurement may be displayed at a time.
Query Syntax
:MEASure:COUNter? [<source>]
The :MEASure:COUNter? query measures and outputs the counter
frequency of the specified source.
Return Format
<source><NL>
<source> ::= count in Hertz in NR3 format
See Also
•
"Introduction to :MEASure Commands"
•
•
•
N O T E
This command is not available if the source is MATH.
N O T E
The :MEASure:COUNter? query times out if the counter measurement is installed on the
front panel. Use :MEASure:CLEar to remove the front-panel measurement before executing
the :MEASure:COUNter? query.
Summary of Contents for InfiniiVision 7000A Series
Page 1: ...Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide...
Page 34: ...34 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 1 What s New...
Page 44: ...44 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 2 Setting Up...
Page 58: ...58 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 3 Getting Started...
Page 750: ...750 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 8 Error Messages...
Page 922: ...922 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide Index...