Commands by Subsystem
5
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
539
:TRIGger:I2S:SOURce:WSELect
Command Syntax
:TRIGger:I2S:SOURce:WSELect <source>
<source> ::= {CHANnel<n> | EXTernal} for the DSO models
<source> ::= {CHANnel<n> | DIGital0,..,DIGital15} for the MSO models
<n> ::= {1 | 2 | 3 | 4} for the four channel oscilloscope models
<n> ::= {1 | 2} for the two channel oscilloscope models
The :TRIGger:I2S:SOURce:WSELect command controls which signal is used
as the word select (WS) source by the serial decoder and/or trigger when
in I2S mode.
Query Syntax
:TRIGger:I2S:SOURce:WSELect?
The :TRIGger:I2S:SOURce:WSELect? query returns the current source for
I2S word select (WS).
Return Format
<source><NL>
See Also
•
"Introduction to :TRIGger Commands"
•
•