Front-Panel Controls
2
6000 Series Oscilloscope User’s Guide
89
The following steps show you how to use delayed sweep. Notice
that the steps are very similar to operating the delayed sweep in
analog oscilloscopes.
1
Connect a signal to the oscilloscope and obtain a stable
display.
2
Press
Main/Delayed
.
3
Press the
Delayed
softkey.
To change the sweep speed for the delayed sweep window, turn
the sweep speed knob. As you turn the knob, the sweep speed is
highlighted in the status line above the waveform display area.
The area of the main display that is expanded is intensified and
marked on each end with a vertical marker. These markers show
what portion of the main sweep is expanded in the lower half.
The Horizontal knobs control the size and position of the
delayed sweep. The delay value is momentarily displayed in the
upper-right portion of the display when the delay time (
)
knob is turned.
To change the sweep speed for the main sweep window, press
the
Main
softkey, then turn the sweep speed knob.
Summary of Contents for InfiniiVision DSO6014L
Page 2: ...Agilent Technologies Agilent 6000 Series Oscilloscopes User s Guide...
Page 59: ...58 6000 Series Oscilloscope User s Guide 1 Getting Started...
Page 109: ...108 6000 Series Oscilloscope User s Guide 2 Front Panel Controls...
Page 125: ...124 6000 Series Oscilloscope User s Guide 3 Viewing and Measuring Digital Signals...
Page 251: ...250 6000 Series Oscilloscope User s Guide 5 Making Measurements...
Page 287: ...286 6000 Series Oscilloscope User s Guide 6 Displaying Data Interpreting Decoded LIN Data...
Page 321: ...320 6000 Series Oscilloscope User s Guide 7 Saving and Printing Data...
Page 370: ......