48
Installation Manual
2
Installation (Getting Started)
Clock Ports/Eye Clock Ports
TX Eye Clock 9.95 Gb/s and 10.71 Gb/s
SMA connector
providing a TX Eye Clock signal (at 1/16 of the line rate) which
can be used to trigger an oscilloscope when examining data
signals.
DS1 Clock In
Bantam 100 ohm (nominal) connector for a DS1
BITS external reference clock input.
2 Mb/s, 2 MHz, 10 MHz Clock In
BNC 75 ohm (nominal)
unbalanced connector for an MTS (2 Mb/s and 2 MHz) external
clock source input. You can also use this connector to input a 10
MHz clock reference.
2 Mb/s, 2 MHz Clock In
Bantam 100 ohm (nominal) connector
for a 2 Mb/s and 2 MHz MTS external clock source input.
TX Eye Clock 52 - 2.5 Mb/s
SMA connector providing a TX Eye
Clock signal (at 1/4 of the line rate) which can be used to trigger
an oscilloscope when examining data signals.
2 MHz Clock Out
BNC 75 ohm (nominal) unbalanced connector
for a 2 MHz MTS clock reference output. Generated relative to
the selected transmit reference clock.
DS1 Clock Out
Bantam 100 ohm (nominal) connector for a DS1
BITS clock reference output. Generated relative to the selected
transmit reference clock.
Installation.book Page 48 Monday, January 12, 2004 1:13 PM