Using Functions
3
N9310A User’s Guide
35
If you want to use an external trigger source, a TTL signal
with 100 ns as the minimum level holding time is required.
Only when the sweep trigger is set to
Key
and the point
trigger is set to
EXT
,
is the sweep repeat able to set to either
Single
or
Cont
. The other combinations of the sweep trigger
and point triggers allows continuous sweep only.
Key
IMM
Pressing
>Sweep mode > RF
, the "
ARMED
" annunciator displays
on the screen
,
indicating the signal generator is ready and waits
for your trigger instruction. Pressing
Trigger key
initiates the signal
generator sweeping over the points automatically.
Key
Key
Pressing
>Sweep mode > RF
, the "
ARMED
" annunciator displays
on the screen
,
indicating the sweep is ready and wait for your
trigger.
Pressing
>Sweep mode > RF
enables the RF sweep, then
pressing the
Trigger key
initiates sweeping over the points
manually.
Sweep
Trigger
Point
Trigger
Sweep Performance
Sweep
Sweep
Sweep