Using Functions
3
N9310A User’s Guide
47
Operation Example
Assume that you are going to generate an I/Q modulated
signal with 1 GHz
carrier frequency, amplitude of –10 dBm
Refer to the following procedures to configure and generate
an I/Q modulated signal:
1
Connecting the external I/Q source to the BNC I and Q
connectors on the rear panel of the signal generator
2
Pressing
presets the signal generator
3
Pressing
> 1 > GHz
sets the CW frequency to 1 GHz
4
Pressing
> –10 > dBm
sets the
CW
amplitude
to
–10 dBm
5
Pressing
enters the I/Q modulation submenu
6
Pressing
I/Q On/Off
enables I/Q modulation
7
Pressing
enables I/Q modulated signal output
Preset
Frequency
Amplitude
I
/
Q
RF
On/Off
Summary of Contents for Keysight N9310A