U1401A Quick Start Guide

Agilent U1401A Handheld 
Multi-Function Calibrator/Meter

Quick Start Guide

The following items are included with your instrument: 

Carrying case and protective holster

Rechargeable battery pack (1.2 V NiMH AA 

×

 8)

Power cord and AC power adapter

Silicone test leads, alligator clips, and a yellow test lead for mA 

simulation

Certificate of calibration

Printed Quick Start Guide

If anything is missing or damaged, please contact the nearest Agilent 
Sales Office.

N O T E

Your multimeter is capable of remote data logging. To use this feature, you will need an IR-USB 
cable (U5481A, purchased separately) and the Agilent GUI Data Logger Software (downloadable 
from 

www.agilent.com/find/hhTechLib

).

WA R N I N G

Ensure that the terminal connections are correct for that particular measurement 
selection before starting any measurement. To avoid damage to the device, do not 
exceed the rated input limit.

C A U T I O N

Degradation of some product specifications can occur in the presence of ambient 
electromagnetic (EM) fields and noise that are coupled to the powerline or I/O cables 
of the instrument. The instrument will self-recover and operate to all specifications 
when the source of ambient EM field and noise are removed or when the instrument 
is protected from the ambient EM field or when the instrument cabling is shielded 
from the ambient EM noise.

Agilent Technologies

U1401A QSG.fm  Page 1  Tuesday, May 15, 2012  11:10 AM

Summary of Contents for U1401A

Page 1: ...ely and the Agilent GUI Data Logger Software downloadable from www agilent com find hhTechLib WARNING Ensure that the terminal connections are correct for that particular measurement selection before starting any measurement To avoid damage to the device do not exceed the rated input limit CAUTION Degradation of some product specifications can occur in the presence of ambient electromagnetic EM fi...

Page 2: ...nts and read the display 4 Press to display dual measurements Measuring DC voltage 1 Set the rotary switch to V or mV Press to select 2 Connect the red and black test leads to the INPUT terminals 3 Probe the test points and read the display 4 Press to display dual measurements Measuring AC current 1 Set the rotary switch to mA Press to select 2 Connect the red and black test leads to the INPUT ter...

Page 3: ...To perform continuity test press to toggle the audible continuity function on or off For continuity test the instrument will beep if the resistance is less than the values indicated below Measurement range Resistance threshold 500 00 Ω 10 Ω 5 0000 kΩ 100 Ω 50 000 kΩ 1 kΩ 500 00 kΩ 10 kΩ 5 0000 MΩ 100 kΩ 50 000 MΩ 1 MΩ 1 Set the slide switch to the M position to disable the output 2 Set the rotary ...

Page 4: ...o any one of the positions 2 Press The annunciator appears 3 Press to cycle through 1 5 V 15 V 1 5 V 15 V 1 5 V and 15 V output modes 4 Select 1 5 V or 15 V 5 Press to output the signal Constant current output 1 Set the rotary switch to any one of the positions 2 Press The annunciator appears 3 Press to cycle through 25 mA 25 mA and 25 mA output modes 4 Select 25 mA 5 Press to output the signal 1 ...

Page 5: ...urns on autorange Press and hold for 1 s Turns on dual display Press Turns on the frequency measurement function Press Enables the shifted functions of the keypad Press Toggles the backlight on or off Press and hold for 1 s Selects output mode and range for voltage and current output With rotary switch at or and with mode enabled press Selects parameter adjustments for square wave output With rota...

Page 6: ...rge cycles before achieving maximum capacity To discharge simply run the multimeter using the rechargeable battery s power until it shuts down or until the low battery warning appears In some instances the multimeter may indicate that the charging is complete after ten minutes or so when charging a new rechargeable battery This is a normal phenomenon with rechargeable batteries Remove the recharge...

Page 7: ...formed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met WARNING A WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in personal injury or death Do not proceed beyond...

Page 8: ...Agilent Technologies Second Edition May 4 2012 Agilent Technologies Inc 2008 2012 U1401 90011 Printed in Malaysia U1401A QSG fm Page 8 Tuesday May 15 2012 11 10 AM ...

Reviews: