CONFigure Subsystem
5
U2300A Series USB DAQ Programming Guide
27
CONFigure:DIGital:DIRection
Syntax
CONFigure:DIGital:DIRection <direction>, (@<ch_list>)
This command is used to configure the selected digital port and the
direction setting for input and output operations of the selected port.
CONFigure:DIGital:DIRection? (@<ch_list>)
The query command returns
"INPut"
or
"OUTPut"
for the specified
channels. Multiple responses are separated by comma.
Supported Model
U2351A, U2352A, U2353A, U2354A, U2355A, U2356A, U2331A
Parameters
Query Returned Format
<direction> ::= {INPut|OUTPut}
Example
CONFigure:DIGital:DIRection INPut, (@501)
CONFigure:DIGital:DIRection? (@501)
//Expected returned string is INPut
See Also
Item
Type
Range of Values
Default Value
<direction>
String
{INPut|OUTPut}
INPut
<ch_list>
Numeric
Channel 501 through 504
N/A
Summary of Contents for U2300A Series
Page 8: ...VIII U2300A Series USB DAQ Programming Guide Contents ...
Page 18: ...1 Introduction to Programming 10 U2300A Series USB DAQ Programming Guide ...
Page 40: ...5 CONFigure Subsystem 32 U2300A Series USB DAQ Programming Guide ...
Page 60: ...6 IEEE 488 Common Command 52 U2300A Series USB DAQ Programming Guide ...
Page 70: ...7 MEASure Subsystem 62 U2300A Series USB DAQ Programming Guide ...
Page 84: ...8 OUTPut Subsystem 76 U2300A Series USB DAQ Programming Guide ...
Page 92: ...9 Root Commands 84 U2300A Series USB DAQ Programming Guide ...
Page 104: ...10 ROUTe Subsystem 96 U2300A Series USB DAQ Programming Guide See Also ROUTe CHANnel RSouRCe ...
Page 130: ...11 SENSe Subsystem 122 U2300A Series USB DAQ ...
Page 162: ...15 WAVeform Subsystem 154 U2300A Series USB DAQ Programming Guide ...
Page 168: ...16 Error Messages 160 U2300A Series USB DAQ Programming Guide ...