11
SENSe Subsystem
120
U2300A Series USB DAQ
[SENSe:]COUNter:TOTalize:UDOWn:SOURce
Syntax
[SENSe:]COUNter:TOTalize:UDOWn:SOURce <mode>, (@<ch_list>)
This command is used to set the clock source of the general purpose
digital counter on the up/down counting process.
[SENSe:]COUNter:TOTalize:UDOWn:SOURce? (@<ch_list>)
The query command returns a string value that indicates the clock source
of the general purpose digital counter.
Supported Model
U2351A, U2352A, U2353A, U2354A, U2355A, U2356A, U2331A
Parameters
Query Returned Format
<mode> ::= {INTernal|EXTernal}
Item
Type
Range of Values
Default Value
<mode>
String
INTernal: Gate is controlled by software
EXTernal: Gate is controlled by
COUNT301_UPDOWN/ COUNT302_UPDOWN
pin
INTernal
<ch_list>
Numeric
301 through 302
N/A
Summary of Contents for U2300A Series
Page 8: ...VIII U2300A Series USB DAQ Programming Guide Contents ...
Page 18: ...1 Introduction to Programming 10 U2300A Series USB DAQ Programming Guide ...
Page 40: ...5 CONFigure Subsystem 32 U2300A Series USB DAQ Programming Guide ...
Page 60: ...6 IEEE 488 Common Command 52 U2300A Series USB DAQ Programming Guide ...
Page 70: ...7 MEASure Subsystem 62 U2300A Series USB DAQ Programming Guide ...
Page 84: ...8 OUTPut Subsystem 76 U2300A Series USB DAQ Programming Guide ...
Page 92: ...9 Root Commands 84 U2300A Series USB DAQ Programming Guide ...
Page 104: ...10 ROUTe Subsystem 96 U2300A Series USB DAQ Programming Guide See Also ROUTe CHANnel RSouRCe ...
Page 130: ...11 SENSe Subsystem 122 U2300A Series USB DAQ ...
Page 162: ...15 WAVeform Subsystem 154 U2300A Series USB DAQ Programming Guide ...
Page 168: ...16 Error Messages 160 U2300A Series USB DAQ Programming Guide ...