7
MEASure Subsystem
58
U2300A Series USB DAQ Programming Guide
MEASure:COUNter:PWIDth?
Syntax
MEASure:COUNter:PWIDth? (@<ch_list>)
This query command returns a numeric value. The returned value is the
pulse width (duty cycle) of the specified counter channel measured in
miliseconds (ms). Multiple responses are separated by commas.
Supported Model
U2351A, U2352A, U2353A, U2354A, U2355A, U2356A, U2331A
Parameters
Remarks
This query requires a channel number to be stated.
Query Returned Format
<value> [ms]
Example
[SENSe:]COUNter:FUNCtion PWIDth, (@301)
MEASure:COUNter:PWIDth? (@301)
See Also
Item
Type
Range of Values
Default Value
<ch_list>
Numeric
301 through 302
N/A