19
Hopper & Hose Set Installation Instructions
1.
Remove the drain tube from the priming valve body using a wrench
2.
Thread in the union fitting into the priming valve body. The square side with the Teflon will
thread into the valve. The other side with the male flare should be facing out. Tighten with an
appropriate wrench.
3.
Thread the nut of the new drain hose onto the fitting and tighten with a wrench.
4.
Remove the suction hose by squeezing the hose clip and pulling straight down.
5.
Insert the hopper’s suction pipe fully into the pump and then squeeze the hose clip and
ensure that it seats fully in the slot.
6.
Thread the hopper onto the suction pipe
7.
Insert the strainer into the bottom of the hopper.
NO.01~07 V:1.0
NO. Parts Name
Q'TY
1.
PLASTIC HOPPER 6200cc
1
2.
HOPPER STRAINER 20
1
3.
HOSE
CLIP 1
4.
O-RING Ø2.4 x Ø19.8 x Ø24.6
2
5.
SUCTION
PIPE
1
6.
DRAIN
TUBE
1
7.
UNION FITTING
PT1/8" x 9/16"-18
1
Summary of Contents for 700W Mechanical