Fastening the counter 

 

Place the counter on the base plate. 

 

Use the 4 allen screws M5x8. Two of them 

have a small hole for the seal wire, use these 

two on the side where you want to attach the 

seal. 

 

First, pull slightly down all 4 screws, and then 

tighten every screw again so that the housing 

is evenly pressed against the mounting plate. 

7.4

 

Attaching the seal 

 

Thread the seal wire through the holes in the 

two screws. 

 

Thread both ends of the wire through a hole 

in the seal. 

 

Slide the seal as close as possible tot he 

meter and at the same time tighten the wire. 

 

Close the seal. 

If the hole of one oft he screws is not accessible, 

you can also drill a small hole in the housing bar 

between the two screws and pull through the seal 

wire here. 
 

Summary of Contents for AgriCounter Drive

Page 1: ...AGRETO electronics GmbH User Manual Acre meter AGRETO AgriCounter Drive...

Page 2: ...ing the mounting plate 12 7 3 Fastening the counter 13 7 4 Attaching the seal 13 8 Working with the device 14 8 1 Reading the area mode 2A 2B 14 8 2 Reading the distance mode 2C 2D 14 8 3 Reading the...

Page 3: ...s designed to measure the number of revolutions of wheels and other rotating parts on all types of machines and devices Activation takes place by direct rotation of the counter itself By multiplying t...

Page 4: ...r DANGER The AGRETO AgriCounter may only be operated by persons who are familiar with the operation of the device CAUTION Keep the work area clean Soiled areas contributes to accidents RISK Risk of in...

Page 5: ...AGRETO AgriCounter must not be operated in explosive areas 5 Technical specifications Packaging dimensions 220x160x50 mm LxWxH Package weight 450 g Device dimensions 73 x 52 x 33 mm WxHxD Weight 230...

Page 6: ...es depending on the path Operating mode 2B Area and hours In this mode the area is counted as in 2A Additionally the operating hours are recorded The counter reacts to vibrations and movements of the...

Page 7: ...ently of the rotation and shows the total number of operating hours too Operating mode 2F Speed In this mode the current speed is displayed by recording the revolutions of the counter around its own a...

Page 8: ...perating mode On delivery the operating mode 2A is preset To change the operating mode press and hold the M button for 3 seconds After releasing the key the display briefly shows MOdE and then the cur...

Page 9: ...m modes 2A 2B 2C 2D 2G This parameter specifies the number of revolutions of the counter around its own axis per 100 meters traveled You can calculate the number from the circumference of the wheel on...

Page 10: ...summation is started after 100 seconds In counting mode this parameter determines the length of a rest period in seconds during which the count continues without interruption If another movement follo...

Page 11: ...to 0 7 Assembly Only start with the assembly once you have clarified whether a change in the configuration is necessary for your application Please read the chapter Configuration before 7 1 Positionin...

Page 12: ...esired position to the desired mounting position Use the mounting plate as a template and mark the 2 holes with a pin Hit one notch each with a grain Drill the 2 holes with a 4 2 mm diameter drill Deb...

Page 13: ...then tighten every screw again so that the housing is evenly pressed against the mounting plate 7 4 Attaching the seal Thread the seal wire through the holes in the two screws Thread both ends of the...

Page 14: ...2B The sum of the counted area in hectares is displayed with 2 decimal places and the ha symbol lights up 8 2 Reading the distance mode 2C 2D The total of the counted distance in kilometers is display...

Page 15: ...is visible as a delimiter it is decimal with 2 decimal places 8 6 Symbols on the display Below the hour display there are various icons for displaying additional information The wavy line means that...

Page 16: ...er displayed is the sum of the hectares The s lights up in the setting mode when a parameter value is expected in seconds The m lights up in setting mode when a parameter value in meters is expected T...

Page 17: ...m properly Insert 2 new AAA batteries into the device in the specified direction Mount the counter again on the mounting plate Seal the device again with a new seal wire and a new seal 10 2 Area is no...

Page 18: ...rs even with minor movements To hold longer periods of rest during operation set the parameter hOLd upwards 10 6 Too many operating hours are counted Perhaps the machine is exposed to light movements...

Page 19: ...rranty period begins with the first accounting to an end customer and ends 5 years from this date of invoice Prerequisite for warranty service are the presentation of the original invoice and complian...

Page 20: ...o technical changes or design changes All information in this manual are supplied without liability despite careful preparation A liability by the author is excluded Copyright 2020 AGRETO electronics...