AGRETO AgriCounter Drive
© AGRETO electronics GmbH
page:9
To determine the area, the parameter
WidE - working width
must be set.
The parameters
SENS
and
hoLd
are only relevant for the hour counting; the
default settings should be suitable for most applications.
To open the parameter menu, briefly press the "M" key. The first parameter that
is relevant for the set operating mode appears on the display.
The name of the parameter is displayed for two seconds, then the set value
appears.
Use the "+" or "-" keys to change the value of the parameter. For parameters
with a large setting range, the value can be changed more quickly by holding
the "+" or "-" button for 3 seconds.
Use the "M" key to change to the next parameter, the set value is saved. After
the last parameter, the first parameter is displayed again.
To exit the menu, press and hold the "M" button for three seconds, or simply
wait 10 seconds without pressing a button.
Parameter r100 – Revolutions per 100 m
(modes 2A, 2B, 2C, 2D, 2G)
This parameter specifies the number of revolutions of the counter around its
own axis per 100 meters traveled.
You can calculate the number from the circumference of the wheel on which the
meter is mounted by dividing 100 by the circumference in meters.
It is better to mark out a distance of 100 meters, drive along it and count the
number of revolutions.
The number can be set with an accuracy of 0.05.
Adjustable range: 10 to 300, default value: 60
Parameter WidE – Working width
(modes 2A, 2B)
This parameter defines the working width of the device in meters. This width is
used to calculate the area. Therefore, take into account possible overlaps.
The number can be set with an accuracy of 0.05.
Adjustable range: 0.05 to 50, default value: 3
Parameter SENS - Sensitivity
(modes 2B, 2D, 2F)
This parameter determines from which intensity of a movement the count is
triggered, ie how strong the vibration or movement must be. The higher the
value, the stronger the movement must be to trigger or continue the count.
0 = highest sensitivity (counts even on very small movements)
2 = a running internal combustion engine is already detected