AGRETO Hydraulic Scale
© AGRETO electronics GmbH
page:9
7
Settings of the Weighing Indicator
The weighing indicator has several adjustable parameters that affect the
operation of the system.
To use the weighing indicator with the three-point scale AGRETO following
parameters are set differently from the default settings when delivered:
BUILD CABLE: 4
(Load cell connection with 4 wires)
BUILD CAP: 6000
(Capacity of the Scale 6.000 kg)
BUILD RES: 5
(Resolution of the weighing indicator to 5 kg)
OPTION FILTER: 4
(Strong damping of the display)
OPTION MOTION: OFF
(ZERO/TARE/SUM always possible)
OPTION Z.RANGE: FULL (Zeroing possible at any load)
SPEC KEY.FN: SHOW.T (Set function key to SUM-function)
SPEC REM.FN: KEY 4 (Remote control Summing key enabled)
SPEC QCK.CAL: ON
(enables the quick calibration)
SERIAL TYPE: PRINT
(Type of output for remote control)
The default setting for the capacity of the display (= maximum weighing range)
is set to 6000. If you must weigh heavier loads than 6000 kg the parameter
BUILD CAP has to be set accordingly higher (up 999,999) so that the display
during operation does not go on overload.
For operations with larger loads, the division upwards should be adjusted as
otherwise the displayed value is not meaningful.
Summary of Contents for B300-V4-K354
Page 1: ...AGRETO electronics GmbH Manual AGRETO Hydraulic Scale Indicator B300 V4 K354 8 5 2017...
Page 21: ...AGRETO electronics GmbH 2 AGRETO 1 2 12 24 3 ZERO f Z inP ZERO f SELECT PRINT f S inP...
Page 29: ...AGRETO electronics GmbH 10 AGRETO 1 2 12 24 Volt 3 ZERO f Z inP 1x ZERO f SELECT PRINT...
Page 45: ...AGRETO electronics GmbH 26 AGRETO 1 2 12 24 3 ZERO f Z inP 1 ZERO f SELECT PRINT...
Page 57: ...AGRETO electronics GmbH 38 AGRETO 1 2 12 24 3 ZERO f Z inP ZERO f SELECT PRINT f S inP...
Page 61: ...AGRETO electronics GmbH 42...