AGRETO LoadCounter II M 

© AGRETO electronics GmbH  

 

page:6 

6.2

 

Operating Keys 

The control buttons are located inside the device and accessible from the back 

with the mounting plate removed. 

To change settings, look at the buttons and 

then turn the device with the display to the 

front to read the display. 

 
 

 

Button  Definition 

Function 

Menu 

Entry into the menu 

Continue to the next parameter, exit from the menu 

Minus 

Back to the previous step 

Decrease a parameter by 1 

Plus 

Continue to the next step 

Increase a parameter by 1 

6.3

 

Setting the operating mode 

On delivery, the operating mode 5A is preset. 
To change the operating mode, press and hold the "M" button for 3 seconds. 

After releasing the key, the display briefly shows "MOdE" and then the current 

setting of the operating mode appears. 
Change to the desired operating mode with the "+" or "-" buttons. 
The "M" key (or if you wait 10 seconds) will save the selection and exit the menu. 
Please note: Changing the operating mode will reset all totals to 0. 

Summary of Contents for BZLC0010

Page 1: ...AGRETO electronics GmbH User Manual AGRETO LoadCounter II M...

Page 2: ...ounter 10 7 Assembly 11 7 1 Positioning the sensor and the magnet 11 7 2 Mounting the sensor and the magnet 12 7 3 Positioning of the meter 13 7 4 Fixing the mounting plate 13 7 5 Fastening the counte...

Page 3: ...Seals Mounting parts Manual 3 Intended use The AGRETO LoadCounter II M is designed for counting loads on manure spreaders with scraper floors and other transport vehicles with moving parts To record t...

Page 4: ...rom tip over fall and inattention while working with the measuring instrument during getting on and off the tractor 4 3 Personal protective equipment WARNING For individuals who work with the device o...

Page 5: ...1 cable length 3m Powered by 2 x AAA batteries Battery life approx 3 years 6 Configuration 6 1 Selection of the operating mode The AGRETO LoadCounter II M has 2 operating modes In the first mode only...

Page 6: ...rom the menu Minus Back to the previous step Decrease a parameter by 1 Plus Continue to the next step Increase a parameter by 1 6 3 Setting the operating mode On delivery the operating mode 5A is pres...

Page 7: ...the PTO shaft moves a little while driving on the road This logic ensures the greatest possible security when recording the number of loads 6 5 Setting the parameters For the correct recording of the...

Page 8: ...can deduct a small safety reserve so that every load is counted safely The set feed rate has no effect here Example PTO shaft on manure spreader Since the number of impulses is very high here it is be...

Page 9: ...e travel time to the nearest unloading location and set approx 90 of this time Parameter SENS Sensitivity operating mode 5B This parameter determines from which intensity of a movement the count is tr...

Page 10: ...et time the count stops and the sum is reset to the value at the beginning of the rest phase The meter is now in idle mode 1 summation is stopped immediately at the end of the movement 20 default 100...

Page 11: ...is attached to one of the scraper floor shafts If there is no suitable option here the magnet can also be attached to the side of a chain wheel or a flange The sensor is attached to a frame part Exam...

Page 12: ...en the sensor in the hole The sensor must protrude at least 10 mm from the bracket The sensor tip must be 5 to 8 mm away from the magnet A 5 5 mm hole or an M5 thread is required for the fastening the...

Page 13: ...ed on the mounting plate Disassemble the meter from the mounting plate Hold the mounting plate in the desired position to the desired mounting position Use the mounting plate as a template and mark th...

Page 14: ...then tighten every screw again so that the housing is evenly pressed against the mounting plate 7 6 Attaching the seal Thread the seal wire through the holes in the two screws Thread both ends of the...

Page 15: ...umber is the sum of the loads 8 2 Reading the hours operating mode 5B In operating mode 5B the sum of the counted loads and the sum of the counted hours are displayed alternately at intervals of 5 sec...

Page 16: ...currently detecting movement or vibration and is in counting mode The round arrow means that pulses are counted now The n lights up in the setting mode when entering the number of pulses The x means...

Page 17: ...nd remove the meter Remove the old batteries and dispose them properly Insert 2 new AAA batteries into the device in the specified direction Mount the counter again on the mounting plate Seal the devi...

Page 18: ...probably relatively low so that the necessary intensity for the count is not reached Set the parameter SENS down so that the counter triggers even with minor movements To hold longer periods of rest...

Page 19: ...e warranty period begins with the first accounting to an end customer and ends 5 years from this date of invoice Prerequisite for warranty service are the presentation of the original invoice and comp...

Page 20: ...ct to technical or design changes All information in this manual is supplied without liability despite careful preparation A liability by the author is excluded Copyright 2021 AGRETO electronics GmbH...

Reviews: