Parameter dELA - (Delay) pause time
The pause time is the minimum time that must pass before a load can be
counted. It starts to run when the sensor has delivered the set number of pulses
and no longer delivers any pulses (for example, if the shaft stops rotating)
1 = lowest adjustable time in seconds
420 = default setting (7 minutes)
9999 = largest adjustable time in seconds
The pause time should include the travel time from the unloading point to the
loading point (for example from the field to the farm), the time for the loading
process itself and the travel time from the loading point to the unloading point
(for example from the farm to the field).
The time should be measured in such a way that even a load without a long
travel time is recorded. It is best to simply add up the time required for a
loading process and 2 times the travel time to the nearest unloading location
and set approx. 90% of this time.
Parameter SENS - Sensitivity (operating mode 5B)
This parameter determines from which intensity of a movement the count is
triggered, ie how strong the vibration or movement must be. The higher the
value, the stronger the movement must be to trigger or continue the count.
0 = highest sensitivity (counts even on very small movements)
2 = a running internal combustion engine is already detected
4 = default
10 = lowest sensitivity (only counts for extreme movements)
The parameter SENS is related to the parameter hoLd, since a movement must
always have a certain intensity and must be present for a certain period of time
in order to trigger the summation.
Parameter hoLd – Holding time (operating mode 5B)
In idle mode, this parameter determines the time in seconds that the counter
waits after a first move to actually start the totalization permanently. If there is
another movement within the set time (which is strong enough), the time from
the first movement is added up and the counter is in counting mode. If there is