background image

SBI 100 User Instructions Manual

3

   

1 General Information and Warnings

1.1 About this Manual

This manual is divided into chapters by the chapter number and the large text at the top 
of a page. Subsections are labeled as shown by the 1 and 1.1 headings shown above. 
The names of the chapter and the next subsection level appear at the top of alternating 
pages of the manual to remind you of where you are in the manual. The manual name 
and page numbers appear at the bottom of the pages.

1.1.1 Special Messages

Examples of special messages you will see in this manual are defined below. The 
signal words have specific meanings to alert you to additional information or the relative 
level of hazard.

CAUTION!
This is a Caution symbol.
Cautions give information about procedures that, if not observed, could result 
in damage to equipment or corruption to and loss of data.

ELECTRICAL WARNING!

THIS IS AN ELECTRICAL WARNING SYMBOL.

ELECTRICAL WARNINGS MEAN THAT FAILURE TO FOLLOW 

SPECIFIC PRACTICES OR PROCEDURES MAY RESULT IN 

ELECTROCUTION, ARC BURNS, EXPLOSIONS OR OTHER HAZARDS 

THAT MAY CAUSE INJURY OR DEATH.

NOTE: This is a Note symbol. Notes give additional and important information, hints 
and tips that help you to use your product.

Summary of Contents for Brecknell SBI-100

Page 1: ...SBI 100 User Instructions AWT 35 501281 Issue AA ...

Page 2: ...ree dimensions of a two dimensional work and the making of a copy in two dimensions of a three dimensional work stored in any medium by electronic means or transmitted in any form or by any means including electronic mechanical broadcasting recording or otherwise without the prior written consent of the copyright owner under license or as permitted by law This publication was correct at the time o...

Page 3: ...bols 13 Turning on and Zeroing the Scale 13 Turning off the Scale 13 Select Unit of Measure 13 Using the Tare 14 Remove the Tare 14 Hold Function with Automatic Zero on Next Weigh 14 Hold Function with Manual Release 15 Removing Hold 16 Print Function 16 Chapter 4 User Configuration Settings 17 Setup Controls 17 Entering Setup 17 Selecting a Parameter 17 Changing Parameter Data 17 Saving Data 18 E...

Page 4: ...2 SBI 100 User Instructions Manual Chapter 7 Error Codes 29 ...

Page 5: ...amples of special messages you will see in this manual are defined below The signal words have specific meanings to alert you to additional information or the relative level of hazard CAUTION This is a Caution symbol Cautions give information about procedures that if not observed could result in damage to equipment or corruption to and loss of data ELECTRICAL WARNING THIS IS AN ELECTRICAL WARNING ...

Page 6: ...tected by an approved ground fault protection device RCD GFCI etc IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN 1 2 2 Routine Maintenance CAUTION THE EQUIPMENT CONTAINS NO USER SERVICEABLE COMPONENTS Installation and maintenance of the equipment must only be carried out by trained and authorised personnel IMPORTANT This equipment must be routinely checked for proper operation and calibratio...

Page 7: ...ned with water containing a small amount of washing up liquid The outside of products waterproofed to IP65 IP66 and IP67 may be washed down with water containing a small amount of proprietary detergent 1 3 2 Training Do not attempt to carry out any procedure on a machine unless you have received the appropriate training or read the Instruction Manual 1 3 3 EMC Compliance Do not attempt to carry ou...

Page 8: ...6 SBI 100 User Instructions Manual 1 4 Declaration of Compliance ...

Page 9: ... 1lb UK EU 3 pin UK 3 pin EU CE approved 816965002719 75 kg x 0 01kg 150lb x 0 02lb AUS SA 3 pin Australia C Tick approved 3 pin South Africa 816965002726 150 kg x 0 02kg 300lb x 0 05lb AUS SA 3 pin Australia C Tick approved 3 pin South Africa 816965002733 300 kg x 0 05kg 600lb x 0 1lb AUS SA 3 pin Australia C Tick approved 3 pin South Africa Scale Indicator Input signal range 0mV 30mV Sensitivity...

Page 10: ...ge of battery is below 5 7V the Low Bat annunciator will be lighted plug in AC adapter to charge the battery When Lo bAt and actual weight is displayed alternately this indicates the voltage of battery is below 5 5V and the scale will be turned off in two minutes automatically AC Adapter 10 5 12VDC 600mA with central positive 5 7 VDC 9 VDC ...

Page 11: ... 1 Connect the Indicator to the Platform Wire the cable attached to the base as shown if necessary RS232 Loadcell socket Power Adapter Socket 4 2 3 1 1 RED 2 RED 3 RED 4 RED 4 2 3 1 1 RED 2 RED 3 RED 4 RED 1 Red Excitation 2 Black Excitation 3 Green Signal 4 White Signal ...

Page 12: ...I 100 User Instructions Manual 2 3 2 Power Supply 2 4 Display and Keypad 6VDC 500mA 230V 50Hz 6VDC 500mA 230V 50Hz On Off Units Tare T kg lb kg lb Hold Low Batt CH AC Max d SBI 100 Zero 0 NET Zero Hold Print ...

Page 13: ... Tare a gross weight Turn the indicator ON or OFF Zero an applied weight Select between units kg or lb Hold a weight Print Annunciator Description Weight is zero Unit of measure Flashing LED means that the weight reading is not stable Tare T On Off Zero Units kg lb Hold Print Zero 0 kg lb ...

Page 14: ...12 SBI 100 User Instructions Manual Tare is activated Battery is charging AC adapter is plugged in Hold is activated Battery is low Annunciator Description NET CH AC Hold Low Batt ...

Page 15: ...ual 13 3 Scale Operation 3 1 Keypress Symbols 3 2 Turning on and Zeroing the Scale 3 3 Turning off the Scale 3 4 Select Unit of Measure short keypress multiple keypress long keypress On Off Zero ZERO 0 On Off Zero Units kg lb kg lb ...

Page 16: ...14 SBI 100 User Instructions Manual 3 5 Using the Tare 3 6 Remove the Tare 3 7 Hold Function with Automatic Zero on Next Weigh 1 2 Tare NET 3 NET 4 NET On Off Zero ZERO 0 1 Hold Print H o ld ...

Page 17: ...SBI 100 User Instructions Manual 15 3 8 Hold Function with Manual Release 2 3 4 1 H o ld Hold Print H o ld 2 3 ...

Page 18: ...emoving Hold 3 10 Print Function For communications to a printer or PC the indicator has to be setup in the following parameters P2 P4 P5 and P6 Refer to Chapter 4 Hold Print H o l d 1 2 Hold Print 3 Print Gross 45 00kg Tare 1 35kg Net 43 65kg ...

Page 19: ...Setup Controls 4 2 Entering Setup 4 2 1 Selecting a Parameter 4 2 2 Changing Parameter Data Moves flashing digit Change flashed digits Saves data and move down to next parameter setting Exits setup mode Hold Print Units Tare On Off Zero kg kg On Off Zero Units Tare Units ...

Page 20: ...18 SBI 100 User Instructions Manual 4 2 3 Saving Data 4 2 4 Exiting Setup Tare On Off Zero ZERO 0 ...

Page 21: ...ions is applied 3 50 Selectable hold window from 3 to 50 divisions Will hold display reading once stable within a selectable weight range to release the hold button must be repressed P3 0 P3 1 P3 2 P3 3 to 50 P4 x RS232 Serial Interface Settings for serial interface 0 No RS232 output 1 Print displayed data once stable when print key is pressed 2 Print gross tare and net weight once stable when pri...

Page 22: ... bytes p Polarity character including minus sign for negative weigh and a space character for positive W1 W7 Weight data dp Decimal point U1U2 Unit measure kg lb or oz Command Action Response W CR Takes a reading over capacity under capacity zero point error reading kg or lb LF U1U2 U3U4U5 CR LF H1H2H3 CR ETX LF ________U1U2 CR LF H1H2H3 CR ETX LF U1U2 CR LF H1H2H3 CR ETX LF p W1W2W3W4W5W6 dp W7U1...

Page 23: ...inus decimal point unit CR EXT Bit Byte 1 Byte 2 Byte 3 0 0 Stable 0 Not Under Capacity 00 Not defined 1 Unstable 1 Under Capacity 01 Normal working mode 1 0 Not at zero point 0 Not over capacity 10 Hold working mode 1 At zero point 1 Over capacity 11 Not defined 2 Always 0 Always 0 0 Gross Weight 1 Net Weight 3 0 eprom OK 1 eprom error Always 0 Always 0 4 Always 1 Always 1 Always 1 5 Always 1 Alw...

Page 24: ... User Instructions Manual 4 4 3 RS 232 Serial Interface Wiring DE 9 Female Scale DE 9 Male Host Pin Name Direction Pin Name Direction 2 TXD Out 2 RXD In 3 RXD In 3 TXD Out 5 SG 5 Ground Pins 1 4 6 7 8 9 not used ...

Page 25: ...n using certified weights to ensure proper operation and accuracy Calibration is not covered under warranty Moves flashing digit Change flashed digits Saves data and move down to next parameter setting Exits setup mode Hold Print Units Tare On Off Zero kg kg Config Menu Avail Settings Definition Detailed Setting P7 00 31 Displayed Resolution 00 500 01 600 02 750 03 800 04 1000 05 1200 06 1500 07 2...

Page 26: ...ivision settings to increase your stability Calibration can be done with 25 to 100 of requested load and can be calibrated with 1 or 2 calibration points 1 2 3 4 Enter in calibration weight from 25 to 100 of full capacity 5 Single point calibration enter the same weight in again and move to step 7 For 2 point calibration enter in the second calibration weight between 25 100 full capacity 6 On Off ...

Page 27: ...SBI 100 User Instructions Manual 25 7 8 9 Tare Tare ZERO 0 ...

Page 28: ...ct specifications and sales brochure Modification of the setting can be accomplished by altering user configuration settings P11 P19 CAUTION Calibration and or configuration of calibration settings of your scale should be accomplished by a trained service technician using certified weights to ensure proper operation and accuracy Calibration is not covered under warranty ...

Page 29: ... 0 1 2 2 Units key configuration 0 kg only 1 lb only 2 units key active kg and lb P12 0 7 7 Power on zero range full scale 0 1 1 2 2 5 3 10 4 20 5 50 6 100 7 no limitation P13 00 15 3 Zero button range full scale 00 1 06 20 12 5 01 2 07 no limit 13 10 02 3 08 1 14 20 03 4 09 2 25 no limit 04 5 10 3 05 10 11 4 P14 0 1 2 0 Signal within power on zero point range 0 current weight 1 calibration zero 2...

Page 30: ...Zero tracking 0 0d AZT off 1 0 25d 2 0 5d 3 1d 4 1 5d 5 2d 6 3d 7 4d 8 5d P17 0 3 2 Data filter 0 very weak 1 weak 2 standard 3 strong P18 0 9 1 Weight stability 0 0 5d 1 1d 2 1 5d 3 2d 4 3d 5 4d 6 5d 7 6d 8 7d 9 8d P19 0 9 1 Overload range full scale 0 0 1 9d 2 101 3 102 4 405 5 110 6 120 7 150 8 200 9 no limitation Config Menu Avail Settings Default Definition Detailed Setting ...

Page 31: ... Remove all loads and zero the scale Capacity exceeded Remove the load and try again If the load is great than 6 kg a scale with a larger capacity is required CAL Er Calibration error Restart calibration Lo bAt Low Battery Recharge the battery Upon initial use it is recommended to charge battery for 8 hours prior to use EEP E0 EEPROM can t be accessed Replace S100 Indicator EEP E1 Configuration se...

Page 32: ...30 SBI 100 User Instructions Manual ...

Page 33: ......

Page 34: ...238 8702 Fax 507 238 8271 Email sales brecknellscales com http www brecknellscales com Brecknell UK Foundry Lane Smethwick West Midlands England B66 2LP Tel 44 0 8452 46 6717 Fax 44 0 8452 46 6718 Email sales brecknellscales co uk http www brecknellscales com ...

Reviews: