5 Maintenance and Repair
Remote-controlled High Grass Rotary Mulcher
agria 9600-80
45
Battery
Check state of charge of the battery every
100 h
Make sure that the ignition is switched off and
that no current consumers are running. Con-
sumers that are not permanently disconnected
will cause a gradual voltage drop.
Check the battery (A/19) with a voltage tester.
The voltage must be above 12.4 V. If the voltage
is too low, charge the battery and repeat the test.
If the battery does not retain sufficient charge
although it is not used, it must be replaced.
Follow the instructions of the battery manu-
facturer!
Charging:
•
Special charger required.
•
Remove the battery from the machine, for
this purpose, disconnect it starting at the
negative terminal.
•
Connect the positive terminal of the battery
to the positive output of the charger, and
likewise for the negative connection.
•
Only switch the charger on after connecting
the battery.
•
Recommended charging current: 1/10 amps
of battery capacity Ah.
•
For recharging use a charger with a con-
stant charging voltage of 14.4 V.
•
The battery is fully charged when the charg-
ing voltage has not increased in 2 hours.
Summary of Contents for 9600-80
Page 4: ...4 Remote controlled High Grass Rotary Mulcher agria 9600 80 Designation of parts Fig A ...
Page 23: ...Remote controlled High Grass Rotary Mulcher agria 9600 80 23 ...
Page 61: ...Remote controlled High Grass Rotary Mulcher agria 9600 80 61 ...
Page 65: ...Remote controlled High Grass Rotary Mulcher agria 9600 80 65 ...
Page 66: ...66 Remote controlled High Grass Rotary Mulcher agria 9600 80 Machine electric diagram ...
Page 70: ...70 Remote controlled High Grass Rotary Mulcher agria 9600 80 ...
Page 73: ...Remote controlled High Grass Rotary Mulcher agria 9600 80 73 Designation of parts Fig C ...
Page 74: ...74 Remote controlled High Grass Rotary Mulcher agria 9600 80 ...
Page 75: ...Remote controlled High Grass Rotary Mulcher agria 9600 80 75 Declaration of Conformity ...