AG-tronik M1 AND REGULATOR PR-9
INSTRUCTIONS FOR USE – rev. 2017-04
12
6. AG-tronik KEYS DESCRIPTION
Keys for turning on, AUTO, MAIN and sections have a LED next to the key, which lights up
or blinks, when the key is on. LEDs are red, except the key for turning on, which has a green
LED. LED for various sections are in two colours (red and green).
Key ON/OFF – when pressing this key, AG-tronik turns on.
Hold the key for at least 3 seconds to turn it off.
Key AUTOMATIC – selection key for automatic or manual
control. LED lights, when automatic control is set. When
the LED blinks, automatic control is set, but the main valve
is shut down due to improper spraying conditions.
MAIN VALVE ON/OFF button; this button opens and
closes junction – sectional valves simultaneously.
INDIVIDUAL SECTION ON/OFF button with two-colour
LEDs; use buttons to open and close individual sections (in
case there are 4 sections, left/right side in case there are
only two selected sections. Section is on, when a RED LED
is on above the button. If the green LED is on, the switch is
on, but not all spraying conditions are met (GPS device
does not "allow spraying", chapter 12 GPS), or speed is
lower than minimum set speed (chapter 9.9 Minimum
speed).
Key PRESSURE INCREASE (manual control) – the key is
intended for increasing pressure in the regulation valve. It
is active only in manual control (LED next to AUTO key is
turned off), and the central valve MAIN must be turned on.
Key PRESSURE DECREASE (manual control) – the key is
intended for decreasing pressure in the regulation valve. It
is active only in manual control (LED next to AUTO key is
turned off), and the central valve MAIN must be turned on.
Key PROGRAM – this key is used for entry in and exit from
programming module, or analysis and exit program
(opposite function of the OK button).
Key FUNCTION – this key returns AG-tronik to its factory
settings.
Keys CURSORS – keys are intended for navigation on the
display and for setting individual values. Central key OK is
a confirmation key, with which set value is confirmed or is
used to exit the menu of quick setting.