Minimum spraying speed:
Setting of minimum spraying speed determines speed at which MAIN valve automatically
opens and closes. Automatic control of MAIN valve is possible only in AUTOMATIC control,
when the MAIN valve is open and at least one section is open.
When spraying speed exceeds “minimum spraying speed”, MAIN valve automatically opens
and vice versa, when spraying speed drops below “minimum spraying speed”, MAIN valve
automatically closes. AG-tronik signalizes if spraying speed is below minimum spraying
speed by automatically turning off LED on the MAIN valve, LED on key AUTO starts to blink
and blinks until spraying speed exceeds “minimum spraying speed” or until MAIN valve or
AUTO control is shut off.
Range of setting “minimum spraying speed” is between 0.5 km/h and 10 km/h.
EXAMPLE: Spraying speed is 10 km/h, and turning speed does not exceed 4 km/h, then the
recommended setting of minimum spraying speed is 5 km/h. When speed exceeds 5 km/h, the
MAIN valve automatically opens.
Simulation:
Simulation is primarily intended for presentation and training or explaining functioning of
AG-tronik. Simulation is activated by changing value to ON, and deactivated by changing
value to OFF or turning off AG-tronik. When simulation is activated, letter S flashes in the
basic menu.
Figure 57 Simulation symbol ON