INSTRUCTIONS FOR USE
AGP 300 – 600 PRO
Rev.02/2019
58
REMEMBER:
•
it is sufficient to tighten the joint by hand (radial sealing);
•
it is sufficient to tighten the joint by a hand tool (axial sealing).
13.10 Other parts
The rest of the vital parts such as filter inserts, pouring sieve, additional equipment, etc. must be
thoroughly cleaned, checked and replaced if necessary, too. Remove the remaining water and
eventual sediments from parts such as suction filters and three-way valves. Grease all moving
and sliding parts of the sprayer.
To protect the appliance against cold, follow the instructions written below:
•
either remove all water from the pump, the regulator, the hoses, the filters and other
elements of the sprayer;
•
either store the appliance in a warm room;
•
or use an agent against freezing (antifreeze) in accordance with the following procedure:
After you have finished cleaning the spraying appliance, completely empty the reservoir and
pour at least 10 litres of antifreeze agent (a mixture of water and antifreeze) and turn on the
pump. Open all valves on the regulator in order the antifreeze agent can reach all hoses and
nozzles.
At the end, empty the remaining agent from the reservoir into the tank and let the pump operate
for few more minutes in order to pump the remaining agent into the tank.
WARNING: If the temperatures get below zero, protect the spraying
appliance against cold, which could damage it!