CO2 Settings Tab
The settings on this tab are for use with a CO2 PPM sensor. Set the minimum CO2 level (level to activate co2 injection
equipment,) maximum CO2 level (level to activate ventilation equipment,) and the hysteresis level. The hysteresis setting is
mutual between the CO2 injection and ventilation equipment.
Lighting Tab
The settings on this tab control how GrowControl will operate lighting equipment. (See the “Lighting Mode” section above.)
The solar set point tells the controller when to differentiate between night and day. The hi-temp shut-down turns off lighting
equipment when the temperature is exceeded to reduce the heat load; all other equipment remains active in the proper
day/night mode.
Minimum
CO2 level
Hysteresis
(Dead band)
Maximum CO2
level
Solar Set
Point
Lighting Mode
Selectors
Maximum
temperature
before lighting
shut-down