8
© Agrowtek Inc. | www.agrowtek.com
To disable the alarm buzzer,
set the alarm to OFF.
Calibration Menu
Calibration can be performed for each sensor with the
LCD interface using either standard calibration wizards,
or advanced manual calibration methods for non-stan-
dard calibration solutions.
The date of the last calibration for each sensor is stored
in memory and displayed at the start of each calibration
wizard.
GPH MNU
H/L
72.0
6.10
1550
600
°F
pH
uS
mV
DWN ENT
UP
EXIT
ALARMS
CALIBRATION
SETUP
PUMPS
MENU
DWN ENT
UP
EXIT
ALARMS
CALIBRATION
SETUP
MENU
DWN ENT
UP
BACK
TEMPERATURE
PH
COND
CALIBRATION
CLEAR ALL
DWN ENT
UP
BACK
LOW: 0.0
HIGH: 0.0
ALARM: OFF
ALARM
1. Select
ALARM: OFF
DWN ENT
UP
BACK
SET ON
SET OFF
SET ALARM
OFF
2. Select
SET ON
then
press
BACK
to exit.
Alarm Buzzer
1. Select
CLEAR ALL
from the calibration
menu.
2. Press
YES
to restore
factory calibration.
GPH MNU
H/L
72.0
6.10
1550
600
°F
pH
uS
mV
DWN ENT
UP
EXIT
ALARMS
CALIBRATION
SETUP
PUMPS
MENU
Clear Calibration
Calibration can be restored to factory defaults by selecting
CLEAR ALL
.
NO
YES
RESTORE TO
FACTORY
CALIBRATION?
DWN ENT
UP
BACK
TIME/DATE
UNITS
LOG INTERVAL
SETUP
NEXT
DWN ENT
UP
BACK
TEMPERATURE
PH
COND
CALIBRATION
CLEAR ALL