WIRING 

 

For the detector wiring, it is necessary to open the detector by pushing on the side parts of the cover 
in order to to access the connection terminals. 
 

      

      

 

 

SUPPLY VOLTAGE 
 

AE09/GM  

 

Model AE09/GM needs to be feed at 230V AC for proper performance. The detector is 
provided together with a 1.8 m cable ready to be connected to a socket. Direct connection to 
CL1 terminal without using the cable is also possible. 
  
 

AE09/GM-12  

 

Model AE09/GM-12 needs to be feed at 12V DC for proper performance. Such tension, from a 
power supply, is to be directly connected to CL2 terminal. 
 

AE09/GM-24  

 

Model AE09/GM-24 needs to be feed at 24V DC for proper performance. Such tension, from a 
power supply, is to be directly connected to CL2 terminal. 

 

OPERATION RELAY. 
 

All models of detectors are provided with a relay outlet through tension-free contacts, that tilts 10 
seconds after the detector goes to alarm state. This outlet may be used to connect an electrovalve for 
the gas supply cut-off or to repeat the detector state in a centralized alarm system.  
 
 
Terminal assignment is as follows: 
 

Common contact 

NC 

Closed contact, in standby 

NA 

Open contact, in standby 

Summary of Contents for AE09/GM-12

Page 1: ...tly on a cutting device and or other auxiliary devices It is provided with Green light indicator for feeding and operation detector Alarm red light indicator Failure orange light indicator Acoustic in...

Page 2: ...emperature may decrease below 10 C or over 40 C In places where dust and dirt may block the sensor In a wet or humid place WARNINGS Installation and dismantling of these devices is to be made by autho...

Page 3: ...to be feed at 12V DC for proper performance Such tension from a power supply is to be directly connected to CL2 terminal AE09 GM 24 Model AE09 GM 24 needs to be feed at 24V DC for proper performance...

Page 4: ...0 v1 1 USER MANUAL www aguilera es Feeding examples for normally fed electrovalves Electrovalves are usually open when being fed When cutting off the power supply blocks the gas flow and manual reset...

Page 5: ...ARM STATE When the level of METHANE gas concentration is over 10 L I E the detector activates 1 time per second the acoustic alarm and the red indicator for ALARM in an intermittent way ALARM STATE If...

Page 6: ...ny case it has been calibrated below the level of gas explosion The detector should be installed between 1 and 4 metres from gas appliances The detector should not be installed in a closed place for e...

Page 7: ...coustic indication intermittent activation Alarm state indicator Red and acoustic indication fixed activation Acoustic alarm piezoelectric buzzer 3300Hz 85 dB Alarm level 10 L I E METHANE gas CH4 Alar...

Page 8: ...08 04 Fax 93 381 07 58 EAST OFFICE Tel 628 92 70 56 Fax 91 754 50 98 NORTHWEST OFFICE C Jos Luis Bugallal Marchesi 9 15008 A Coru a Tel 98 114 02 42 Fax 98 114 24 62 SOUTH OFFICE Edificio METROPOL 3...

Reviews: