TECHNICAL CHARACTERISTICS 

 

 

AE09/GM 

AE09/GM-12 

AE09/GM-24 

Supply voltage:

 

230V AC

 

12V DC

 

24V DC

 

Heating cycle consumption:

 

13 mA

 

31 mA

 

110 mA

 

Standby consumption:

 

12 mA

 

13 mA

 

70 mA

 

Alarm consumption:

 

14 mA

 

56 mA

 

122 mA

 

Classification: 

Type-A device 

Relay contacts:

 

C, NC and NA voltage-free.

 

Relay contact maximum current:

 

8A 250VAC/30VDC

 

Operation indicator 

Green, fixed activation 

Heating cycle indicator 

Activation of Failure (orange)  and Alarm (red)  

indicators alternatively 

Failure state indicator 

Orange, fixed activation 

Pre-alarm state indicator 

Red and acoustic indication, intermittent activation 

Alarm state indicator.  

Red and acoustic indication, fixed activation 

Acoustic alarm:

 

piezoelectric buzzer, 3300Hz, 85 dB

 

Alarm level:

 

10% L.I.E. METHANE gas(CH

4

)

 

Alarm confirmation:

 

10 seconds

 

Relay activation delay:

 

8 seconds

 

Initial heating period: 

120 seconds 

Temperature range:

 

0º  -  +50º C  (room temperature).

 

Humidity range:

 

Relative humidity 10% - 90% with no condensation

 

Casing material 

White ABS

 

Dimensions:

 

130 x 70 x 52 mm

 

Weight 

300 gr 

133 gr 

137 gr 

 

 

 

 

 
 
 
 

 
 
 
 

 

Please, keep these instructions in a safe place.  

.

 

 

 

For environment preservation, the electric or electronic unit is not to be treated as 
domestic waste at the end of its lifetime. Please, make selective collection taking it to 
specific collecting points for the recycling of electric and electronic units in your 
town/city. 

Summary of Contents for AE09/GM-12

Page 1: ...tly on a cutting device and or other auxiliary devices It is provided with Green light indicator for feeding and operation detector Alarm red light indicator Failure orange light indicator Acoustic in...

Page 2: ...emperature may decrease below 10 C or over 40 C In places where dust and dirt may block the sensor In a wet or humid place WARNINGS Installation and dismantling of these devices is to be made by autho...

Page 3: ...to be feed at 12V DC for proper performance Such tension from a power supply is to be directly connected to CL2 terminal AE09 GM 24 Model AE09 GM 24 needs to be feed at 24V DC for proper performance...

Page 4: ...0 v1 1 USER MANUAL www aguilera es Feeding examples for normally fed electrovalves Electrovalves are usually open when being fed When cutting off the power supply blocks the gas flow and manual reset...

Page 5: ...ARM STATE When the level of METHANE gas concentration is over 10 L I E the detector activates 1 time per second the acoustic alarm and the red indicator for ALARM in an intermittent way ALARM STATE If...

Page 6: ...ny case it has been calibrated below the level of gas explosion The detector should be installed between 1 and 4 metres from gas appliances The detector should not be installed in a closed place for e...

Page 7: ...coustic indication intermittent activation Alarm state indicator Red and acoustic indication fixed activation Acoustic alarm piezoelectric buzzer 3300Hz 85 dB Alarm level 10 L I E METHANE gas CH4 Alar...

Page 8: ...08 04 Fax 93 381 07 58 EAST OFFICE Tel 628 92 70 56 Fax 91 754 50 98 NORTHWEST OFFICE C Jos Luis Bugallal Marchesi 9 15008 A Coru a Tel 98 114 02 42 Fax 98 114 24 62 SOUTH OFFICE Edificio METROPOL 3...

Reviews: