K65C/K75C/K95C
6-5
K65C/K75C/K95C
6-5
2
1
2
1
2
1
2
1
(8)
Remove the protective caps
from the hoses of the multi-purpose
bucket (6-12/1).
(9)
Swing up the protective flaps
of the quick-action couplings of the
quick-change device (6-12/2) and
connect the hydraulic hoses of the
multi-purpose bucket with the quick-
action couplings of the quick-
change device by pushing them
firmly in (6-12).
CAUTION
When making connections, make
sure that the hydraulic connections
are clean and completely connected.
Dismounting
(1)
Place the multi-purpose
bucket firmly on the ground.
(2)
Stop the engine.
(3)
Remove the pressure from the
hydraulic lines. For this purpose,
move the hand lever for the auxiliary
hydraulics (4-12/1) back and forth
several times.
(4)
Dismounting takes place in the
reverse order of mounting. How-
ever, to unlock the multi-purpose
bucket, the release button for the
quick-change device (4-13/2) must
be used.
CAUTION
The hydraulic quick-change device
must only be locked when an
attachment has been mounted.
NOTE
The type plate is on the rear of the
bucket, on the right-hand side
beneath the cross arm.
Figure 6-12
Figure 6-12
(8)
Remove the protective caps
from the hoses of the multi-purpose
bucket (6-12/1).
(9)
Swing up the protective flaps
of the quick-action couplings of the
quick-change device (6-12/2) and
connect the hydraulic hoses of the
multi-purpose bucket with the quick-
action couplings of the quick-
change device by pushing them
firmly in (6-12).
CAUTION
When making connections, make
sure that the hydraulic connections
are clean and completely connected.
Dismounting
(1)
Place the multi-purpose
bucket firmly on the ground.
(2)
Stop the engine.
(3)
Remove the pressure from the
hydraulic lines. For this purpose,
move the hand lever for the auxiliary
hydraulics (4-12/1) back and forth
several times.
(4)
Dismounting takes place in the
reverse order of mounting. How-
ever, to unlock the multi-purpose
bucket, the release button for the
quick-change device (4-13/2) must
be used.
CAUTION
The hydraulic quick-change device
must only be locked when an
attachment has been mounted.
NOTE
The type plate is on the rear of the
bucket, on the right-hand side
beneath the cross arm.
Summary of Contents for AL 65
Page 8: ...Safety regulations...
Page 29: ...Signs...
Page 38: ...Technical data...
Page 60: ...Description...
Page 72: ...Operation...
Page 83: ...Attachments...
Page 91: ...Rescue towing lashing lifting by crane...
Page 100: ...Maintenance...
Page 120: ...Malfunctions causes and remedies...
Page 123: ...Protection against theft...
Page 126: ...Appendices...
Page 127: ......
Page 128: ......
Page 131: ......
Page 134: ...K65C K75C K95C K65C K75C K95C B B...
Page 135: ...K65C K75C K95C K65C K75C K95C C C...
Page 136: ...K65C K75C K95C K65C K75C K95C D D...
Page 137: ...K65C K75C K95C K65C K75C K95C E E...
Page 138: ...K65C K75C K95C K65C K75C K95C F F...