12
increments. The timer will start and the unit will
begin heating as necessary to maintain the Spa
setpoint temperature for this duration. At the end of
the timed period, the unit will automatically go to
the last operational state (POOL HEAT, POOL
COOL, POOL AUTO, SPA, or OFF). Once the unit
turns on, the display will toggle between the cur-
rent Spa water temperature and the current
operating state (“Heating” for example). Pressing
the MENU button will change the display to show
the time remaining on the timer. Press the MENU
button again to go back to the current status.
The control saves the setpoint changes in non-volatile
memory and begins using them for heat demand
decsions after both the UP and DOWN buttons have
been released for 2+ seconds.
REMOTE Mode is accessed by pressing and holding
the UP and DOWN buttons simultaneously for 3 sec-
onds. When exiting the REMOTE mode, the control
always selects the OFF Mode.
If the UP, DOWN or MENU buttons are pressed while
in REMOTE mode, the display will read “Exit Remote
Mode to Adjust Temp”. Mode and temperature set-
points are not changed. Press and hold the UP and
DOWN buttons for 3 seconds to exit REMOTE Mode.
The INSTALLER/SERVICE menu can be accessed by
pressing and holding the UP and MENU buttons for 3+
seconds. The INSTALLER/SERVICE menu does not
affect operation of the unit which continues to operate
in the background. When in this mode, pressing the
UP or DOWN buttons will toggle through the various
information reported. Some items (Fault History and
Sensor Temperatures) have multiple values (press UP
or DOWN buttons to scroll through the additional infor-
mation. The service display mode may be exited to
return to the previous display be pressing the UP and
MENU buttons or it will automatically be exited if no
button is pressed within 60 seconds.
HPPH Control Menus
The USER menu is accessed by pressing and holding
the MENU button on the HPPH display for 3+ seconds.
This menu is intended for use by the end user to
change temperature settings and pump periods as
desired. There are different features and settings
required for different Model types. The model types
shown are HEAT ONLY, POWER DEFROST and
HEAT/COOL. The following tables outlines the items
noted on the display in HEAT ONLY, POWER
DEFROST and HEAT/COOL configurations, the
default values and range of adjustable values as well
as a brief description of the feature.
length of time for the timed SPA heating operation.
Pressing the UP button will increase the timer in 15
minutes increments (up to a total of 6 hours maxi-
mum). Pressing the DOWN button will decrease
the timer by 15 minute increments. The timer will
start and the unit will begin heating as necessary
to maintain the Spa setpoint temperature for this
timer duration. At the end of the timed period, the
unit will automatically return to the last operational
state (POOL HEAT, POOL COOL, POOL AUTO,
SPA, or OFF) of the control. Once the unit turns
on, the display will toggle between the current Spa
water temperature and the current operating state
(“Heating” for example). Pressing the MENU but-
ton will change the display to show the time
remaining on the timer. Press the MENU button
again to go back to the current status.
For HEAT/COOL models, the mode selections are:
OFF – POOL HEAT – POOL COOL – POOL AUTO
– SPA – TIMED SPA.
On HEAT/COOL models, there are additional opera-
tional modes available as noted below:
1. When POOL HEAT mode is selected, each press
of the UP or DOWN buttons will increase /
decrease the pool heating setpoint temperature.
Holding the UP or DOWN buttons down will speed
up the change of the temperature values.
2. When POOL COOL mode is selected, each press
of the UP or DOWN buttons will increase /
decrease the pool cooling setpoint temperature.
Holding the UP or DOWN buttons down will speed
up the change of the temperature values.
3. When POOL AUTO mode is selected, each press
of the UP or DOWN buttons will increase /
decrease the pool setpoint temperature. Holding
the UP or DOWN buttons down will speed up the
change of the temperature values.
4. When SPA mode is selected, each press of the UP
or DOWN buttons will increase / decrease the spa
setpoint temperature. Holding the UP or DOWN
buttons down will speed up the change of the tem-
perature values.
5. When TIMED SPA mode is selected, the display
will read “Up or Dn to Set”. This tells the user to
press the UP or DOWN buttons to set the desired
timer for timed SPA heating operation. Pressing
the UP button will increase the timer in 15 minute
increments (up to a total of 6 hours). Pressing the
DOWN button will decrease the timer by 15 minute