5271022-BTG-A-0916
Johnson Controls Unitary Products
45
PERFORMANCE DATA - 2 TON
Multipliers for determining the performance with other indoor sections.
NOTE:
For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
CONDENSER-ONLY DATA (OUTDOOR UNIT)
MODEL
SATURATED SUCTION
@ COMPRESSOR
Outdoor Ambient Temperature
55 °F
65 °F
75 °F
85 °F
95 °F
105 °F
115 °F
T (°F)
P (PSIG)
MBH
KW
MBH
KW
MBH
KW
MBH
KW
MBH
KW
MBH
KW
MBH
KW
TF3B2421SS
35
107
22.0
1.37
20.8
1.52
19.7
1.68
18.6
1.86
17.5
2.06
16.2
2.30
14.9
2.56
40
118
24.3
1.37
22.9
1.52
21.7
1.68
20.6
1.85
19.3
2.05
18.0
2.29
16.6
2.56
45
130
26.6
1.37
25.3
1.51
23.9
1.68
22.6
1.86
21.2
2.05
19.8
2.29
18.3
2.56
50
142
29.1
1.36
27.7
1.51
26.2
1.67
24.7
1.86
23.3
2.05
21.8
2.29
20.2
2.56
55
156
31.8
1.35
30.3
1.50
28.6
1.68
27.0
1.86
25.6
2.04
23.9
2.28
22.1
2.56
Notes:
1. For Outdoor Unit (Condenser) performance only. Data does not include the effects of air handler power or heat.
2. Performance based on 15°F subcooling and 15°F superheat at the Outdoor Unit base valves.
a. Increase capacity by 1% for each 2°F increase in subcooling.
b. Decrease capacity by 1% for each 2°F decrease in subcooling.
3. Maximum recommended condensing temperature is 140°F.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
TF3B2421SS
INDOOR COIL MODEL NO.
CF24AXA1
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
IDCFM
600
800
1000
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
55
T.C.
20.5
22.7
22.5
25.4
25.7
22.7
24.3
24.1
27.0
26.7
24.8
26.0
25.7
28.7
27.6
S.C.
19.6
18.1
15.4
15.6
11.7
21.7
21.0
17.7
17.8
12.7
24.8
23.9
19.9
20.0
13.7
KW
1.33
1.33
1.33
1.33
1.34
1.40
1.40
1.40
1.40
1.42
1.47
1.48
1.48
1.48
1.49
65
T.C.
20.1
21.5
21.9
24.1
25.3
22.0
23.1
23.4
25.5
26.6
24.0
24.7
25.0
27.0
27.8
S.C.
19.1
17.5
15.1
15.1
11.5
21.1
20.4
17.3
17.3
12.7
24.0
23.4
19.6
19.5
13.9
KW
1.47
1.47
1.47
1.47
1.48
1.55
1.55
1.55
1.55
1.56
1.62
1.63
1.63
1.63
1.64
75
T.C.
19.6
20.3
21.3
22.8
24.9
21.4
21.8
22.8
24.0
26.5
23.1
23.3
24.2
25.3
28.1
S.C.
19.6
16.9
14.8
14.6
11.3
21.4
19.9
17.0
16.8
12.7
23.1
22.9
19.2
18.9
14.0
KW
1.62
1.61
1.62
1.61
1.62
1.69
1.69
1.69
1.69
1.70
1.77
1.77
1.77
1.77
1.78
85
T.C.
18.8
19.5
20.1
22.0
23.7
20.4
20.7
21.5
23.4
25.1
22.1
21.9
22.9
24.8
26.6
S.C.
17.9
16.5
14.2
14.2
11.0
20.4
19.0
16.4
16.5
12.3
22.1
21.5
18.5
18.7
13.6
KW
1.81
1.80
1.81
1.80
1.81
1.88
1.88
1.89
1.88
1.89
1.96
1.96
1.96
1.96
1.97
95
T.C.
17.9
18.6
19.0
21.2
22.5
19.5
19.5
20.3
22.8
23.8
21.1
20.4
21.6
24.4
25.1
S.C.
17.9
16.0
13.7
13.9
10.7
19.5
18.1
15.7
16.2
12.0
21.1
20.4
17.7
18.5
13.2
KW
2.00
1.99
2.01
2.00
2.00
2.07
2.07
2.08
2.07
2.08
2.15
2.15
2.16
2.15
2.16
105
T.C.
17.1
17.3
18.2
19.9
21.5
18.7
18.3
19.4
20.9
22.9
20.2
19.3
20.5
22.0
24.2
S.C.
17.1
15.3
13.2
11.9
10.3
18.7
17.2
15.3
14.7
11.6
20.2
19.3
17.3
17.5
12.9
KW
2.26
2.26
2.28
2.27
2.27
2.34
2.33
2.35
2.34
2.34
2.41
2.40
2.42
2.41
2.42
115
T.C.
16.3
16.0
17.4
18.5
20.5
17.8
17.1
18.4
19.0
22.0
19.4
18.1
19.4
19.6
23.4
S.C.
16.3
14.6
12.8
9.9
9.9
17.8
17.1
14.9
13.2
11.2
19.4
18.1
16.9
16.6
12.5
KW
2.53
2.53
2.55
2.54
2.54
2.60
2.59
2.61
2.60
2.61
2.67
2.66
2.68
2.67
2.68
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Green shaded cells are ACCA (TVA) conditions.
Blue shaded cells are AHRI conditions.