“ROLL-IN” devices: Hinges on
glass doors (see Fig. 9) must be
fixed and mounted with a cover. In
case of deviations, contact the
maintenance service (see
→
10.4).
Fig. 9 Hinges of glass doors (symbol
representation)
CAUTION
Leakage of fluids from damaged
packaging. Drainage of condensed
water from glass doors. Slipping
hazard.
►
Check for puddle formation in front
of and below the device.
►
Remove spilled fluids/condensation
water immediately.
NOTICE
•
Material
damage
due to improper use.
►
Operate the device in the operating position and
in a stable position.
►
Operate the device only on the designated
adjustable feet.
►
Regularly check that the device is in good
condition. Damage must be repaired immediately.
►
Avoid transmission of pulsations and vibrations
to the device.
►
Avoid external force to the device such as
careless movements with floor trucks or floor
cleaning machines.
•
Property
damage
due to improper use.
► Operate the device in the climate class indicated
on the additional stickers on the power rating plate
(see
→
Chapters 2.2.1 and 2.3).
► The ambient temperature must not be less than
16°C (60.8°F).
►
Check the internal temperature (see
→
Chapter 4.1).
►
Stored goods must be checked by the operator
in the case of power failure (temperature control).
►
Check regularly for foreign objects in the goods
area. Incorrectly stored goods must be removed
immediately.
►
Remove food residues, such as spilled liquids
and packaging residues (see
→
Chapter 10.1.1).
►
Regularly check that the glass doors are closed.
In the case of special climate conditions with high
atmospheric humidity, condensate formation
(condensation water) can occur in the interior of
the device or at the air outlet openings above. This
condensation must be removed for hygiene
reasons.
WARNING
For devices of type R-290: Drying of
condensation water by rubbing.
Electrostatic discharge and spark
formation. Sparks can ignite the leaking
refrigerant when the refrigerant circuit is
damaged/not sealed.
Risk of fire.
►
To remove condensation, use a damp
cloth or sponge.
► Do not use dry cloths or sponges for
rubbing dry.
9.1 Loading
Access to the goods is from the front.
The device must only be loaded with goods when the
temperature specified for the product has been
reached. Check the temperature display on the
internal thermometer (see
→
Chapter 4.1 Fig. 2).
CAUTION
Breakage of glass doors. Cutting
injuries to the body.
► With clear passageways take note
of opened glass doors.
►
Do not apply a load onto the glass
doors.
► Do not drive the shopping cart/roller
container/pallet truck into open or
closed glass doors.
►
Drive into the device with the roller
container/pallet truck carefully.
► Bring the roller container/pallet
truck to a standstill before hitting the
device.
►
Close glass doors immediately
after loading.
CAUTION
Improper assembly of the
shelves/display shelves. Danger of
injury due to falling of shelves/display
shelves loaded with goods.
►
Displays/display shelves must fully
engage in the slots provided.
CAUTION
Entering the device areas.
Cutting injuries in the case of material
breakage.
Danger of falling. Impact hazard due
to the risk of falling goods.
► Do not climb onto or into the device
during loading.
CAUTION
Falling objects.
Impact injury. Cutting injury in the
case of glass breakage.
►
Do not place objects on the
device.
►
Do not place heavy bottle packs
in the upper displays/display
shelves.
With cover
True
False