347345_1116 33
AHT Cooling Systems GmbH
2. Product description
2.1 General information
AHT products meet the requirements of the EU directive
2011/65/EC (RoHS2) for preventing dangerous substances
from entering electrical and electronic devices and the EU
regulation 1907/2006 (REACH) on registering, assessing
and approving chemicals.
When it came to designing the product, the manufacturer
ensured that the appliances were environmentally friendly
and easy to dispose of. This was especially the case with
the refrigerant propane (R-290) and with pentane, the blow
-
ing agent for the insulating foam. Propane has no ozone
depletion potential (ODP) and a very minimal greenhouse
gas potential (GWP) of 3.
2.2
Technical specifications
The important technical specifications are found on the rat
-
ing plate (see
➙
Chapter 2.2.1).
External dimensions
See
➙
Model types –
Overview
Airborne noise emission
Emission sound pressure
level < 70 dB(A)
Maximum load
storage racks
- See
➙
the following
table and Chapter 9.1
-
Label inside on the upper
right of the appliance ceil-
ing, next to the rating plate.
Storage rack
Max. load [kg/m²]
Standard shelf / display
rack (grating)
115
Bottom plate / bottom shelf
including grating
600
technical interfaces:
Power supply
(appliance-
specific, adhere to the
specifications on the rating
plate, see
➙
Chap. 2.2.1)
with
plug types
(appliance
connection)
-
3 x 380-420V 50Hz /N/P
CEE 5x16A
or
-
3-pole, 4-wire ground
208-240 V/ 60 Hz
NEMA L15-20P
Minimum requirements
for the connection cable:
Minimum cross section
2.5 mm² (14AWG)
Defrost water outlet
DN 40
communication
AHT Inter Cabinet BUS
(ICB)
Bus cable
CAT 5-S/FTP (PIN 1-8 al
-
located)
Brine connection:
Dutch connection
3/4”
(supply/return)
light control
(control of external day/
night signal)
Potential-free contact
Electrical fuse protection (see chapter 7.2):
All combinations must have a 3-pole circuit breaker.
Circuit
breaker
Nominal
current [A]
Trip
charac-
teristic
Type
Re-
sidual
current
[mA]
for
208-
240V
for
380-
420V
MCB
(LS)
20
16
C
(delay)
_
_
RCCB
(FI)
≥ 40
≥ 40
_
G (surge
current
strength)
30
RCBO
(FI-LS)
20
16
C
(delay)
G (surge
current
strength)
30
If you need further information, please contact maintenance
services (see
➙
Chapter 10.4).
Subject to technical modifications.
2.2.1 Rating plate and serial number
Please refer to the information on the rating plate when
handling the appliance. The rating plate can be found as a
label on the upper right of the appliance ceiling. It contains
important technical specifications, including:
∙
Appliance designation and appliance type
∙
Serial number
∙
Climate class (see
➙
Chapter 2.3)
∙
Nominal voltage and nominal frequency
∙
Nominal current and nominal consumption
∙
Refrigerant and amount employed
∙
Net volume
∙
Manufacturing date
∙
Test mark
∙
Technical specifications for interior lighting (optional)
∙
And other technical specifications
2.3
Intended use
The appliance is only suitable for the storage of packaged
frozen food products.
Property damage
due to improper use.
▶
Do not operate the appliance above the conditions
specified in the climate class (ambient temperature,
relative air humidity).
▶
The ambient temperature must never fall below
16°C (60.8°F).
Do not operate the appliance above the
climate class
specified on the rating plate (see
➙
Chapter 2.2.1) or the
additional label.
The climate class is specified on the rating plate (see
➙
Chapter 2.2.1) or the additional label on the appliance.
NOTICE