347345_1116 35
AHT Cooling Systems GmbH
Depending on the operating status, this lamp will light up
green (normal operation), yellow (defrosting), or red (alarm).
Fig. 3: Status LED
Status lED:
Cannot be acknowledged. Appears until the fault is cor
-
rected.
5. transport and storage
After delivery, check the appliance for transport damage.
In case of damage, contact maintenance services (see
➙
Chapter 10.4).
Damage to the refrigerant circuit. refriger-
ant can escape and cause an explosive gas/
air mixture. Risk of fire.
▶
Do not expose the appliance to tempera-
tures higher than 70°C (158°F) during stor
-
age and transport.
▶
Be sure that the room is well ventilated.
▶ Observe the safety instructions and warn
-
ings for appliances with flammable refriger
-
ants (see
➙
Chapter 1.6.2.1).
▶ Contact maintenance services (see
➙
Chapter 10.4).
WArNiNG
transporting the appliance with lift trucks.
Risk of personal injury in the event of a col
-
lision.
▶
Follow transport routes for lift trucks.
▶ Securely fasten transported goods.
▶ Only trained personnel are permitted to
operate lift trucks.
NOTICE
Material damage
due to transport and storage.
▶ Only transport and store the device in the operating
location (transport frame).
▶ If, however, the appliance has been tilted, wait at
least 2 hours before commissioning.
▶ Bear in mind the appliance’s centre of gravity for
safe lifting of the load with the forklift truck. Informa
-
tion about this can be found on the front and rear of
the appliance packaging.
▶ Only the AHT installation service may remove the
transport pallet on which the appliance rests.
Status-LED
WArNiNG
▶ Ensure complete accessibility to the installation area
upon delivery. (Consider clearance heights/widths,
the height of the installation space and sufficient
manoeuvrability.)
6. unpacking
During unpacking, inspect the appliance for damage (dents,
scratches).
In case of damage, contact maintenance services (see
➙
Chapter 10.4).
WArNiNG
Disposal of packaging material and films. Risk of
suffocation.
▶ Keep packaging material and films out of the reach
of children.
▶ Do not allow children play with these materials.
WArNiNG
Damage to the refrigerant circuit. refriger-
ant can escape and cause an explosive
gas/air mixture. Risk of fire.
▶
Be sure that the room is well ventilated.
▶ Observe the safety instructions and warn
-
ings for appliances with flammable refriger
-
ants (see
➙
Chapter 1.6.2.1).
▶ Contact maintenance services (see
➙
Chapter 10.4).
cAutiON
Sharp appliance edges. Heavy appliance
parts. Cutting injury on
the hands. Hands
can be pinched.
▶ Take care of fingers and hands during
unpacking.
▶ Wear protective gloves.
NOTICE
Material and property damage
due to missing appli-
ance parts.
▶ Check the packaging for loose parts.
▶ Do not dispose of loose parts. Contact maintenance
services if the installation location of loose parts
cannot be found (see
➙ Chapter 10.4).
7. Set up and installation
Set up and installation of an appliance or appliance group
(assembly, sealing) may only be performed by specialist
personnel. This work must be carried out in accordance
with the VENTO GREEN MC FREEZE system commission
-
ing manual. This manual is provided to specialist personnel.
The installation of the appliance / appliance group and the
external unit must be carried out by specialist personnel in
consultation with the operator.
Before delivery and installation of the appliance, the opera
-
tor must supply the following fully functional infrastructures
Status lED