347345_1116 36
AHT Cooling Systems GmbH
and bears responsibility for these systems and interfaces to
be connected:
∙
Power supply (power supply company)
∙
Sewage system for draining defrost water (defrost
water outlet)
∙
Overriding store control system
∙
Remote data transmission access for remote mainte-
nance (optional)
Technical specifi cations for interfaces see
➙
Chapter 2.2.
Technical modifi cations to the appliance only in consulta-
tion with and approval from the manufacturer.
NOTICE
Material and property damage
due to accumulation of
warm exhaust air (heat accumulation).
▶
The exhaust air must be able to escape unhindered
on the top of the appliance.
▶ Overhangs or false ceilings directly on the upper
edge of the appliance may only be installed after
consulting with the manufacturer.
The store’s feed signal for the light control must be con-
nected to the input box (additional box) included on the
appliance for the store’s light control system.
Fig. 4: Setup in a VENTO appliance group (example)
WArNiNG
risk of appliance tipping. Persons can be
trapped.
▶ Remove the transport pallet only when the
appliance is in the stable, fi nal installation
position.
▶
Use tilt protection.
▶ The appliance can only be positioned with
the use of tilt protection.
▶
Tilt protection installation service (see
➙
Fig. 5.1) may only be removed when there
is no longer a risk of tipping. In the event
the appliance is to be set up on an island,
secure it using the wall or the appliance next
to it, for example. (Tilt protection installation
service is included as an accessory to the
AHT installation service.)
▶ Do not remove additional appliance-specifi c
tilt protection after installation (see
➙
Fig. 5.2).
▶ Observe separate assembly instructions.
External unit
Brine circuit
▶ If there are any questions, contact mainte-
nance services (see
➙
Chapter 10.4).
Fig. 5.1: Tilt protection
Fig. 5.2: Appliance-specifi c
tilt protection installation service
WArNiNG
in the event of damage to the refrigerant
circuit, refrigerant can escape and cause an
explosive gas/air mixture. Risk of fi re (see
➙
chapter 1.6.2.1).
▶
Do not close air vents in the appliance hous-
ing (for example, front ventilation grilles or
upper air ducts). If accessories have to be
installed, care must be taken to ensure that
no air vents are closed.
▶ The appliance must only be installed in well
ventilated rooms.
▶
Do not install the appliance in basement
rooms or rooms below ground level.
▶ Conduits and wall ducts underneath and
behind the appliance must be sealed in a
suitable fi re-resistant manner.
▶
Drilling or other work on the appliance is not
permitted.
▶
Do not pinch or bend tubes.
▶ Minimum area for installation 300 m².
cAutiON
improper assembly of the shelves / display
racks. Risk of injury due to falling shelves
/ display racks loaded with products or as
a result of shelves / display racks loaded
with products.
▶ When hanging shelves / display racks, they
must be snapped into place in the provided
openings.
Entering the appliance area. Cutting injuries
caused by material breakage. risk of falling.
risk of impact due to the possibility of fall-
ing parts.
▶
Do not climb on top of or into the appliance.
Sharp appliance edges, heavy appliance
parts.
c
utting injury on the hands. Hands can be
pinched.
▶ Take care of fi ngers and hands during set up
and installation.
▶ Wear protective gloves.