background image

3. If holding time is more than one second, the LED will blink faster and faster. 
If holding time is more than 5 seconds, the LED will be solid for 3 seconds to 
indicate that the resetting is successful. Otherwise, repeat step 2.

 

Note: 

Reset to factory will remove Smart Plug from the Z-Wave network.

 

Use this 

procedure only in the event that the network primary controller missing or 
otherwise inoperable. 

 

4. SECURITY AND NON-SECURITY FEATURES OF SMART PLUG 

1. The function of the Smart Plug as a security and non-security device is identical. 
 
2. When a node includes into a S2 Z-Wave network, the node supports S2 authenticated class and 
so do the supported CCs

.

 

 
3

. Commands List

 

 

Included Non-Secure Network 

Included Secure Network 

Non-secure 
supported 
Command 
Classes 

COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

COMMAND_CLASS_SWITCH_BINARY_V1 

COMMAND_CLASS_ASSOCIATION_V2 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 

COMMAND_CLASS_TRANSPORT_SERVICE_V2 

COMMAND_CLASS_VERSION_V2 

COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 

COMMAND_CLASS_METER_V3 

COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 

COMMAND_CLASS_POWERLEVEL_V1 

COMMAND_CLASS_CONFIGURATION_V1 

COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 

COMMAND_CLASS_SCENE_ACTIVATION_V1 

COMMAND_CLASS_SECURITY0_V1 

COMMAND_CLASS_SECURITY2_1 

COMMAND_CLASS_SUPERVISION_V1 

COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4

 

COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

COMMAND_CLASS_TRANSPORT_SERVICE_V2 

COMMAND_CLASS_SECURITY0_V1 

COMMAND_CLASS_SECURITY2_V1 

COMMAND_CLASS_SUPERVISION_V1 

 

Security 
Supported 
Report 
Command 
Classes 

 

COMMAND_CLASS_SWITCH_BINARY_V1 

COMMAND_CLASS_ASSOCIATION_V2 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 

COMMAND_CLASS_VERSION_V2 

COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 

COMMAND_CLASS_METER_V3 

COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 

COMMAND_CLASS_POWERLEVEL_V1 

COMMAND_CLASS_CONFIGURATION_V1 

Summary of Contents for HA-ZW-5PAB

Page 1: ...ters regardless of vendor to increase reliability of the network Smart Plug is also a security Z Wave device and supports the Over The Air OTA feature for the product s firmware upgrade If you want yo...

Page 2: ...ht is blue when the device is turned off the light changes to red 2 TECHNICAL SPECIFICATIONS Power supply 230V 10 50Hz Rated load current 10A Power consumption 1 5W Power output 2300W Operational temp...

Page 3: ...frame 2 To remove the product from the Z Wave network a Insert the Smart Plug to power socket the LED will follow the status on or off of its load s power level b Set the Z Wave network main controlle...

Page 4: ...V2 COMMAND_CLASS_SWITCH_BINARY_V1 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 COMMAND_CLASS_TRANSPORT_SERVICE_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2...

Page 5: ...ommand such as short pressing 2 Sending Meter Report 3 Sending Device Reset Locally 5 2 Basic Command Basic CC maps to Switch Binary CC 5 3 Configuration Command Smart Plug offers a wide variety of ad...

Page 6: ...0 The function is disabled 1 Send Basic report 2 Send Basic report only when Load status is not changed by Z Wave Command Default value 1 Parameter size 1 byte Parameter No 04 LED Load indicator mode...

Page 7: ...the parameters 101 104 to default Possible values 85 Parameter size 1 byte Parameter No 101 Setting time for sending meter report watt The interval time of sending meter report watt to associated devi...

Page 8: ...ssible values 5 2678400 5 2678400s Default value 3600 one hours Parameter size 4 byte Parameter No 254 Enable disable the configuration command Lock unlock all configuration parameters Possible values...