Aibot X6 V2, Operation
29
3.2.3
Temperatures
Limitation
The operation temperatures for a safe use of the Aibot X6 V2 are limited.
Adhere to the stated temperature ranges.
Aibot X6 V2
* Maximum temperature for flights above 5.5
kg takeoff weight is +30
°C
Batteries
3.2.4
Engine and engine controller
Limitation
The engines, engine controllers and propellers have limitations. The design and
construction of the system does not allow to exceed these limitations. Do
always follow the procedures and maintain the limitations published in this
manual to avoid a usage out of the operational range.
3.2.5
Payload and Weight
Limitation
CAUTION
Limited payload
The specified data refer to the International Civil Aviation Organisation (ICAO)
conditions for International Standard Atmosphere (ISA). Never exceed the
maximum takeoff weight as it may cause an overload of the Aibot X6 V2.
CAUTION
Limited operation time
The flight time of the Aibot X6 V2 depends on the installed payload.
WARNING
Unusual behaviour of the Aibot X6 V2
The flight characteristics of the Aibot X6 V2 vary significantly from the normal
behaviour if the system is used close to its limits.
Temperature
°C
Outside air temperature (OAT)
−10
…
+40 *
Storage temperature
Dry conditions and not in direct sunlight
0
…
+40
Temperature
°C
Operation temperature
−10
…
+40
Storage temperature
0
…
+40
Charging temperature
0
…
+45
Deadweight with optionally build in telemetry and
live video transmitter equipment [%]
3,400 ±
4%
Maximum takeoff weight (MTOW) [g]
6,600
Maximum payload for the camera gimbal [g]
2,000
Maximum payload for the on-top mount [g]
650
Total payload [g]
3,200 (incl. batteries)
AiPower LiPo (5S 5000
mAh) [g]
610