46
Aibot X6 V2, Operation
CAUTION
Automatic system check
After connecting the batteries, the Aibot X6 V2 needs time to perform an auto-
matic system check and a calibration of the internal sensors. Do not move the
Aibot X6 V2 during that period and wait, until the “wait” signal on the RC trans-
mitter telemetry menu has switched to “ready”.
In the meantime the following checks are carried out:
3.5.3
Before Transportation
Before Transporta-
tion
Description
Condition/Action
RC
Telemetry display
Select
Refer to "2.3.4 Telemetry Menu" for
more information.
RC
LiPo batteries voltage
Check at the telemetry display that
the batteries are fully charged (21.0
V).
RC
GPS signal and accuracy
Check (minimum 6 satellites avail-
able).
RC
Magnetic field
No error.
X6
Waypoints
Upload waypoints as required
GE
Orientation of Aibot X6 V2 and
operator
Check the takeoff orientation and
your orientation.
GE
Takeoff area
Clear and safe
GE
Airspace
Clear and safe
GE
Wind
Check wind speed and direction
GE
Emergency briefing
Perform an emergency briefing
Description
Condition/Action
X6
Payload
Remove
X6
LiPo batteries
Remove