Aibot X6 V2, Operation
61
3.8.5
Lost RC communication
Abnormal Proce-
dures
Identification
•
Voice Response: "Failsafe activated / RC lost!"
•
Signal tone of the RC transmitter.
•
Status LEDs of the Aibot X6 V2 are flashing blue.
•
Deactivated RC transmitter.
Recommended Procedure
a) If communication is re-established:
b) If communication can NOT be re-established:
CAUTION
RC Lost Failsafe
If the communication to the Aibot X6 V2 is lost, the RC Lost Failsafe will be
performed automatically. Refer to "3.4.9 RC Lost Failsafe" for more informa-
tion.
Prevention
•
Carefully check the launch site and the flight area for any disturbances.
•
Check the battery power of the RC transmitter before flight execution.
•
Respect the limitations and procedures given by the RC transmitter manual.
Description
Condition/Action
GE
Distance to Aibot X6 V2
Reduce the distance between the RC
Transmitter and the Aibot X6 V2 if
possible. Keep visual contact.
RC
Toggle Switches
Do not change
Description
Condition/Action
X6
Flight
Abort and identify reasons for distur-
bance.
Description
Condition/Action
GE
Announcement
"EMERGENCY LANDING"
GE
Landing Site
Secure from any obstacles if possible
GE
Landing
Monitor the automatic landing proce-
dure. Be prepared for re-establishing
the communication.
X6
After Landing
Plug off the LiPo Batteries immedi-
ately.