35
J2012-01User Manual
Chapter 3 Sub-system Configuration Setup
To ensure J2012-01 can work properly, provide high performance, and maintain enhanced
durability. J2012-01 has implemented SCSI Enclosure Services to monitor the status of
power supply, system cooling fan, and working temperature. It also has various indicators
to deliver the status of fail devices, such as power supply and cooling fan. Furthermore,
you can receive information directly from the front indicators to know how your enclosure
works.
For detailed information, please visit
http://www.t10.org
If you are a member of the T10 working group, the Standard which controlled by T10
technical committee, could be found at
http://www.t10.org/cgi-bin/ac.pl?t=f&f=ses2r19a.pdf
3.6.1 SES pages supported are listed below.
00h - List of supported diagnostic pages
01h - SES configuration
02h - SES enclosure control / enclosure status
04h – SES String In
05h – SES Threshold Out / In
07h - SES element descriptor
0Ah - SES additional element
0Eh - SES download microcode control / SES download microcode status
3�6�2 SES elements supported are listed below�
02h - Power Supply
03h – Cooling
04h - Temperature Sensor
0Eh - Enclosure
12h - Voltage
17h - Array Device
3�6 SES Inband Features