Chapter 3 Sub-System configuration Setup
J4076-01 User's Manual
52
3.6.4.4 Enclosure Element
(A) Enclosure Control Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON CONTROL
SELECT
PRDFAIL DISABLE RST SWAP
Reserved
1
RQST
IDENT
Reserved
2
POWER CYCLE
REQUEST
POWER CYCLE DELAY
3
POWER OFF DURATION
REQUEST
FAILURE
REQUEST
WARNING
Field
Value
RQST IDENT
Please refer to section “SES Element Control Functions” for details.
REQUEST FAILURE Please refer to section “SES Element Control Functions” for details.
REQUEST
WARNING
Please refer to section “SES Element Control Functions” for details.
(B) Enclosure Status Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON STATUS
Reserved PRDFAIL DISABLE
SWAP
ELEMENT STATUS CODE
1
IDENT
Reserved
2
TIME UNTIL POWER CYCLE
FAILURE
INDICATION
WARNING
INDICATION
3
REQUEST POWER OFF DURATION
FAILURE
REQUESTED
WARNING
REQUESTED
Field
Value
ELEMENT STATUS
CODE
OK
IDENT
0: Identify LED of Hub is OFF
1: Identify LED of Hub is solid ON
FAILURE
REQUESTED
Set by the REQUEST FAILURE on Enclosure Control Element
WARNING
REQUESTED
Set by the REQUEST WARNING on Enclosure Control Element