Chapter 4. BMC Configuration Settings
J4078-01 User Manual
4.3.2 Configure Serial Command Line Interface
The RS232 setting - baud rate: 38400 bps, data bits: 8, parity: none, stop bits: 1, flow
control: none
4.3.2.1 How to configure T10 zoning
After enabling T10 zoning, five predefined groups are Group1, Group8, Group9, Group10,
and Group11. Each PHY should be in one of the five groups, and all PHYs in a wide port
should be in the same group. Each PHY in Group1 can access any PHY in other groups, and
vice versa. Each PHY in Group8 cannot access any PHY in Group9, and vice versa.
The command syntax is "phyzone phy_index group." The following example shows how
to setup one drive accessed only by the first port and another drive accessed only by the
second port.
The configuration for the example is
( A ) PHY8 - PHY11 for the first wide port of HUB
( B ) PHY4 - PHY7 for the second wide port of HUB
( C ) PHY20 - PHY35 for drives on EDGE
Step 1
Read the current group for PHY4 of HUB.
cmd> phyzone 4
Phy 4 for Zone Group 1
Step 2
Assign the second port (PHY4 - PHY7) for Group9.
cmd> phyzone 4 9
cmd> phyzone 5 9
cmd> phyzone 6 9
cmd> phyzone 7 9
Step 3
Assign the first port (PHY8 - PHY11) of HUB for Group8.
cmd> phyzone 8 8
cmd> phyzone 9 8
cmd> phyzone 10 8
cmd> phyzone 11 8
Step 4
Assign the drive on PHY20 of EDGE to be accessed only by the first port of HUB
instead of the second port.
cmd> phyzone 20 8
Step 5
Assign the drive on PHY21 of EDGE to be accessed only by the second port of HUB
instead of the first port.
cmd> phyzone 21 9
Step 6
Rest HUB and EDGE for taking effect with the new settings.
cmd> reset