24
Chapter 3. Sub-system Configuration Setup
J4060-02 User Manual
3.5.2 How to configure T10 zoning
After enabling T10 zoning, 5 predefined groups are Group1, Group8, Group9, Group10
and Group11.
Each PHY should be in one of the 5 groups, and all PHYs in a wide port should be in
the same group.
Each PHY in Group1 can access any PHY in other groups, and vice versa. Each PHY in
Group8 cannot access any PHY in Group9 and vice versa.
The command syntax is "phyzone phy_index group". The following example shows
how to setup one drive accessed only the first port and another drive accessed only by
the second port.
The configuration for the example is
(A) PHY20 - PHY23 for the first wide port of HUB
(B) PHY16 - PHY19 for the second wide port of HUB
(C) PHY20 - PHY21 for drives on EDGE
Step 1
: Read the current group for PHY16 of HUB
cmd> phyzone 16
Phy 16 for Zone Group 1
Step 2
: Assign the second port (PHY16 - PHY19) of HUB for Group9
cmd> phyzone 16 9
cmd> phyzone 17 9
cmd> phyzone 18 9
cmd> phyzone 19 9
Step 3
: Assign the first port (PHY20 - PHY23) of HUB for Group8
cmd> phyzone 20 8
cmd> phyzone 21 8
cmd> phyzone 22 8
cmd> phyzone 23 8
Step 4
: Assign the drive on PHY20 of EDGE to be accessed only by the first port of HUB
instead of the second port
cmd> phyzone 20 8
Step 5
: Assign the drive on PHY21 of EDGE to be accessed only by the second port of
HUB instead of the first port
cmd> phyzone 21 9
Step 6
: Rest HUB and EDGE for taking effect with the new settings.
cmd> reset
Summary of Contents for JBOD Series
Page 1: ...UM_J4060 02_v3 1_121619 J4060 02 12Gb s SAS JBOD Series User s Manual...
Page 40: ...31 J4060 02 User Manual Chapter 3 Sub system Configuration Setup...
Page 45: ...36 Chapter 3 Sub system Configuration Setup J4060 02 User Manual...
Page 99: ...90 Chapter 4 BMC Configuration Settings J4060 02 User Manual 5 Processing 6 Update successful...
Page 102: ...93 J4060 02 User Manual Chapter 4 BMC Configuration Settings...