Importé par :
AIC International - 44980 Ste Luce sur Loire - France
-39-
Importé par :
AIC International - 44980 Ste Luce sur Loire - France
-40-
- Press and hold down the
MODE
button (the screen goes
black quickly) then release. The display shows 2000 by
default.
- Press to select the first number. The number
selected flashes.
- To increase the value of the selected number, press
Press to decrease the value.
- Press to select the following numbers and repeat the
previous steps.
- To return to a previous value press .
- Press and hold down the
MODE
button (then release) to
confirm the value of the alarm and go to the next setting.
- The calendar is displayed in Month/ Date format in yellow
with the year in blue. Proceed as indicated above to select
and change the values of the calendar.
Press and hold down the
MODE
button (then release) to
confirm the calendar settings and go to the time setting.
- The display shows the time in minutes format: Seconds in
yellow and hour (in 24 H format) in blue. Proceed as
indicated above to select and change the values of the clock.
Press and hold down the
MODE
button (then release) to
confirm the time setting and return to standby mode.
In standby mode, the meter displays the CO2 concentration
in ppm for the room in yellow. The temperature and humidity
are displayed in blue.
Step 3: Enabling/ Disabling the alarm.
In standby mode,
press The symbol appears above the temperature
display.
This confirms that the alarm is enabled. If the symbol does
not appear on the display, this means the alarm is disabled.
IMPORTANT:
when the sound of the alarm is disabled, the
alarm will not be heard (the visual display is maintained). It is
recommended not to disable the alarm. The alarm is
only available when the set CO2 value is exceeded.