INSPECTION AND CLEANING

To clean the Kera sit2sit, wipe it down with a damp cloth using warm water and a disinfectant cleaner. 
Do not use harsh solvents such as phenol and chlorine as it may damage the hoist’s finish. Follow 
laundering instructions on the Backstrap. Do not submerge any other components for cleaning.

It is recommended that the Kera sit2sit and its accessories are regularly cleaned and/or disinfected 
between each use.

MAINTENANCE AND USER INSPECTIONS

The caregiver should always inspect the hoist for hygiene, wear and damage before each use to ensure 
the safety of all users. 

Every 12 months a more detailed inspection should be carried out by a suitably qualified technician.

Contact HT Systems if you have any concerns about the condition or safety of the hoist.

The lifetime of this product in normal use is 8 years if all maintenance and servicing is carried out  
in accordance with the manufacturer’s instructions and demonstrably recorded.

WARRANTY INFORMATION

HT Systems, at its sole discretion, warrants that it will repair or replace defective components or faulty 
workmanship for a warranty period of one (1) year from the date of manufacture of the product.

A warranty claim may not be accepted where:

 

Notice has not been given within four (4) weeks of the defect or faulty workmanship being first noticed.

 

Damage is caused by negligence, accident or deliberate abuse, product modification, incorrect use, 

incorrect storage or maintenance and continued use of the part after the defect or faulty workmanship 

is first noticed.

 

We reserve the right to substitute components of equal or better quality on the particular items being 

repaired or replaced.

There will be no extensions to the original warranty period for any product that has been repaired or replaced. 

PRODUCT INFORMATION

Product Information

Kera80

Kera120

Product weight

35kg*

Outside width

605mm

Minimum internal width (legs closed)

415mm

Maximum internal width (legs open)

1100mm

Length – handle upright

950mm

Length – handle down

1230mm

1580mm

Handle height (upright)

1300mm

1550mm

WARNING: Heavy. Use safe lifting practice

USER RECOMMENDATIONS

User Recommendations

Kera80

Kera120

User weight

Up to 80kg

Up to 120kg

User height

From 130cm to 190cm

WARNING: Before attempting a transfer, a clinical assessment of the user’s suitability for use with this 
hoist should be carried out by a qualified health professional.

IDENTIFYING YOUR KERA SIT2SIT MODEL

The Kera sit2sit high models are raised by 80mm 
and are identified by the green raiser as shown in 
the image above.

The Kera sit2sit 80 and 120 models are identified 
by different length handles and the sticker affixed 
to the handle as shown in the image above.

The Kera sit2sit serial number is affixed to the right 
side of the hub by the Knee Supports as shown in 
the image above.

Summary of Contents for HT Systems KERA SIT2SIT

Page 1: ...KERA SIT2SIT HOIST Owner and Instructional Manual ...

Page 2: ...r should be trained in the use of this hoist This hoist is designed for use with at least one caregiver It is important to be aware that the materials used in this hoist may not be hypo allergenic or fire retardant Avoid placing fingers or other body parts in obvious pinch points Ensure that the hoist and Backstrap is not damaged or worn before operation The Backstrap should be used for all transf...

Page 3: ...t 16 Footboxes 17 Kera sit2sit Owners Information 18 Product Information 18 User Recommendations 19 Identifying Your Kera sit2sit Model 19 Copyright Haipai Transfer Systems Ltd 2022 MAN001 Version F No part of this user manual may be copied distributed reproduced scanned or stored on any electronic database whether in whole or in part in any form or by any means Due care has been taken to ensure a...

Page 4: ...on for long periods of time The Kera sit2sit is only to be used for the purposes as described in this manual KERA SIT2SIT DIAGRAM USER AND CAREGIVER ASSESSMENT A clinical assessment of the user s suitability for use with the Kera sit2sit should be carried out by a qualified health professional The user does not need to be weight bearing but will require some level of flexibility in their lower joi...

Page 5: ... handle can move freely through its range of motion and locks in position when the lock lever is released SQUEEZE LEVER Squeeze and hold Lock Lever when moving handle SQUEEZE LEVER For setup hold the lock lever and move the caregiver handle until the Chestpad is just above the knees and thighs of the user Check that the legs are spread open to fit around the chair To spread the legs of the Kera si...

Page 6: ... end Follow the same procedure on the other side with the same number of loops from the end STEP 3 CHESTPAD ON THE LAP The Chestpad must be pressed securely to the user s chest and lap to promote a comfortable and secure transfer The following steps should be followed to ensure a good fit to the lap Pull the index pin up Push the Chestpad slider forward until it slightly squashes the foam against ...

Page 7: ...he Backstrap fitted low on the back and make sure it is as tight as possible Try pushing the Chestpad into the user s stomach by one or two more holes When lifted up the user should end up less hunched over and the Backstrap shouldn t slip up as much STEP 5 LIFTING FROM SEAT Once you have fitted and tightened the Backstrap you can perform the lifting from the seat Take a firm two handed grip on th...

Page 8: ...red onto the following steps can be followed to lower them Always check that there is a chair behind the user and the chairs brakes are applied before operating the Lock Lever 100MM Spread the legs of the Kera sit2sit to fit around the chair Position the user with 100mm gap between the back of their calves and the chair edge Lock the wheels by standing on the red Brake Pedal Ensure you have a firm...

Page 9: ...s arms and feet won t catch on anything as you move the Kera sit2sit away Carefully move the Kera sit2sit away from the user Remove the Backstrap from behind the user FOOTBOXES The Footboxes are an additional component offered and can be fitted to replace the Footplates by a suitable Technician Contact your region s distributor for further information The Footboxes allow the user s feet to be rest...

Page 10: ...ct or faulty workmanship being first noticed Damage is caused by negligence accident or deliberate abuse product modification incorrect use incorrect storage or maintenance and continued use of the part after the defect or faulty workmanship is first noticed We reserve the right to substitute components of equal or better quality on the particular items being repaired or replaced There will be no ...

Page 11: ...AUM12 9 181022 For more detailed information please refer to our website htsystems com au htsystems co nz Hapai Transfer Systems Ltd 2022 ...

Reviews: