10
5.13
Final Assembly
5.13.1 Pull Seal Installation
If the breather hole is open, do NOT mount
the housing in a position where the front
face plate is pointed upward.
To maintain enclosure protection ratings of NEMA-4
and IP65, the pull seal (provided in the hardware kit)
must be installed in the front face plate. It is
recommended that the pull seal be installed in a cool,
dry environment to prevent trapping moisture inside
the housing. See FIGURE 14.
NOTE: Pull seal installation allows the housing’s front
end to be pointed upward.
FIGURE 14 Breather Hole
Proper installation of the pull seal is as follows:
1. If the housing assembly is not already removed
from the base assembly, do so now; see the
Disassembly and Mounting
section at the
beginning of these instructions.
2. Obtain a rubber pull seal from the hardware kit
(Part Number 315 2569 001). An extra pull seal
is also provided. See FIGURE 15.
FIGURE 15 Pull Seal
3. Insert the long end of the pull seal into the
breather hole starting from the front side of the
face plate. See FIGURE 16.
FIGURE 16 Inserting the Pull Seal
4. Reach into the housing and grip the pull seal’s
long end
from the back of the front face plate.
Steadily pull the long end until the head of the
pull seal is flat against the front of the end cap.
See FIGURE 17.
NOTE: The Pull Seal’s long end will stretch when
pulled through the breather hole.
FIGURE 17 Installing the Pull Seal
Breather Hole
Front
Face
Plate
"Long End"
Head
Face Plate
Housing
Pull Seal
Housing (Cut away)
Grip and Pull