background image

5.13.2 Housing Assembly

1. The lens support screw is provided to support

the rail assembly. Adjustment will only be
necessary if the rail assembly is rotated at angle
other than horizontal. If the screw head is not
touching the cover when the cover is installed,
loosen the screw until it does. See FIGURE 18.

FIGURE 18  Support Screw Adjustment

2. Replace the cover onto the base assembly by

grasping the cover and gently pushing it over the
end cap and o-ring. Make sure the o-ring is not
pinched. The safety cable can be routed between
the cover and the base. See FIGURE 19

FIGURE 19  Replacing the Cover

3. Align the cover holes with the base assembly

holes and replace the two M4 screws and
washers. This secures the cover onto the rest of
the housing.

NOTE: Make sure the breather hole is located at the
bottom of the housing. If it is not, remove both front
retaining rings and the face plate. Orient them so the
breather hole is located at the bottom and the gaps in
the retaining rings are centered over the breather hole.
See FIGURE 20.

FIGURE 20  Location of the Breather Hole

11

Lens 

Support

Screw

Base Assembly

Cover

End Cap

Front Face Plate

Retaining Ring 

Breather Hole (centered)

 

 

 

 

 

 

 

 

Summary of Contents for HS9385 Series

Page 1: ...Screw Bushing Ground Wire Terminal Lug Power Cable Rail Assembly M4 Screws Mounting Holes I N S T A L L A T I O N A N D O P E R A T I N G I N S T R U C T I O N S W W W A I G I S M E C H C O M EXTRA L...

Page 2: ...mpletion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power sour...

Page 3: ...MA 3R and IP54 The HS9385 Series housings include a breather hole in the front face plate The breather hole prevents the accumulation of moisture inside the housing when installed in areas of high hum...

Page 4: ...able Requirements Video Transmission Coaxial Cable Type RG 59 U Runs 1000ft RG 11 U Runs 2000ft Cable Size Outside diameter between 4 6mm and 7 9mm 0 181in and 0 312in Cable Shape Round Shield 93 Brai...

Page 5: ...t the base before installing the camera but it may be mounted anytime during the installation process See FIGURE 3 FIGURE 3 Mounting the Base Assembly 5 6 Camera Lens Installation Place the camera len...

Page 6: ...y tighten all fittings to ensure a liquid tight seal Not doing so could damage the camera the housing or both If a sealant will be used be sure it is a neutral cure type Sealants that release acetic a...

Page 7: ...8 Securing the Ground Wire 4 Connect both the line and neutral wires of the power cord to the terminal block Make sure the line and neutral wires are connected to the correct positions on the termina...

Page 8: ...in to 7 9mm 0 312in See FIGURE 11 2 Attach a BNC connector to the coax and connect it to the camera Pull any excess cable through the liquid tight fitting and tighten the flex fitting to 4 0N m to 4 5...

Page 9: ...Cable Wiring If using a pan tilt with a feed through cable insert the camera lens function cable in through the right fitting at the rear of the cradle Wire the functions as described above or as nee...

Page 10: ...ed from the base assembly do so now see the Disassembly and Mounting section at the beginning of these instructions 2 Obtain a rubber pull seal from the hardware kit Part Number 315 2569 001 An extra...

Page 11: ...ched The safety cable can be routed between the cover and the base See FIGURE 19 FIGURE 19 Replacing the Cover 3 Align the cover holes with the base assembly holes and replace the two M4 screws and wa...

Page 12: ...100 0100 002 AIG 07 05 Printed in U S A 2005 Aigis Mechtronics 1124 Louise Road Winston Salem NC 27107 5450 Tel 336 785 7740 Fax 336 785 7744 Data subject to change without notice...

Reviews: