background image

1

UNPACKING

This electronic equipment should be unpacked and
handled carefully.

Check for the following items:
Quantity

Part Description

1

1/4-20 x 3/8in. BHCS (Button Head Cap
Screw)

1

1/4-20 x 1/2in. BHCS

1

1/4-20 x 5/8in. BHCS

1

1/4-20 x 3/4in. BHCS

1

1/4-20 x 7/8in. BHCS

4

3.2mm (0.125in.) plastic spacer

4

0.4mm (0.016in.) plastic spacer

2

Nylon bushings

1

3/8in. NPT plug

1

Small flex fitting

2

Pull Seals

2

Large flex fitting

3

Cable ties

If an item appears to have been damaged in shipment,
replace it properly in its carton and notify the shipper.
If any items are missing, notify Aigis Mechtronics. The
shipping carton is the safest container in which the unit
may be transported. Save it for possible future use.

2

SERVICE

If the unit ever needs repair service, the customer
should contact Aigis Mechtronics for return
authorization and shipping instructions.

3

CARE AND MAINTENANCE

There are no moving parts in this unit. Regularly
scheduled maintenance will help prolong the
operational life of this unit. Clean the viewing window
as needed with a mild, nonabrasive detergent in water
and a soft cloth.

4

DESCRIPTION

The HS9385 Series of environmental housings are
attractive aluminum enclosures designed for outdoor
CCD camera installations. 

4.1

Enclosure Rating

4.1.1

NEMA-3R and IP54

The HS9385 Series housings include a breather hole in
the front face plate. The breather hole prevents the
accumulation of moisture inside the housing when
installed in areas of high humidity. With the breather
hole open, the HS9385 Series housings meet the
enclosure rating requirements of NEMA-3R and IP54.

4.1.2 NEMA-4 and IP65

For installations requiring an enclosure rating of
NEMA-4 or IP65, the breather hole must be plugged
using the pull seal (Part No. 315 2569 001) provided in
the hardware kit. Refer to Final Assembly under
INSTALLATION for proper installation.

SAFETY PRECAUTIONS 

CAUTION: TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT REMOVE COVER
(OR BACK). NO USER SERVICEABLE PARTS
INSIDE.  REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

This symbol indicates the presence of

uninsulated “dangerous voltage” within

the product’s enclosure. This may

constitute a risk of electric shock.

The user should consult the operating

and maintenance (servicing)

instructions in the literature

accompanying the appliance.

3

Attention: Installation should be performed by

qualified service personnel only in accordance

with the National Electrical Code or applicable

local codes.

Power Disconnect. Units with or without 

ON-OFF switches have power supplied to the unit

whenever the power cord is inserted into the

power source; however, the unit is operational

only when the ON-OFF switch is in the ON

position. The power cord is the main power

disconnect for all units. 

Summary of Contents for HS9385 Series

Page 1: ...Screw Bushing Ground Wire Terminal Lug Power Cable Rail Assembly M4 Screws Mounting Holes I N S T A L L A T I O N A N D O P E R A T I N G I N S T R U C T I O N S W W W A I G I S M E C H C O M EXTRA L...

Page 2: ...mpletion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power sour...

Page 3: ...MA 3R and IP54 The HS9385 Series housings include a breather hole in the front face plate The breather hole prevents the accumulation of moisture inside the housing when installed in areas of high hum...

Page 4: ...able Requirements Video Transmission Coaxial Cable Type RG 59 U Runs 1000ft RG 11 U Runs 2000ft Cable Size Outside diameter between 4 6mm and 7 9mm 0 181in and 0 312in Cable Shape Round Shield 93 Brai...

Page 5: ...t the base before installing the camera but it may be mounted anytime during the installation process See FIGURE 3 FIGURE 3 Mounting the Base Assembly 5 6 Camera Lens Installation Place the camera len...

Page 6: ...y tighten all fittings to ensure a liquid tight seal Not doing so could damage the camera the housing or both If a sealant will be used be sure it is a neutral cure type Sealants that release acetic a...

Page 7: ...8 Securing the Ground Wire 4 Connect both the line and neutral wires of the power cord to the terminal block Make sure the line and neutral wires are connected to the correct positions on the termina...

Page 8: ...in to 7 9mm 0 312in See FIGURE 11 2 Attach a BNC connector to the coax and connect it to the camera Pull any excess cable through the liquid tight fitting and tighten the flex fitting to 4 0N m to 4 5...

Page 9: ...Cable Wiring If using a pan tilt with a feed through cable insert the camera lens function cable in through the right fitting at the rear of the cradle Wire the functions as described above or as nee...

Page 10: ...ed from the base assembly do so now see the Disassembly and Mounting section at the beginning of these instructions 2 Obtain a rubber pull seal from the hardware kit Part Number 315 2569 001 An extra...

Page 11: ...ched The safety cable can be routed between the cover and the base See FIGURE 19 FIGURE 19 Replacing the Cover 3 Align the cover holes with the base assembly holes and replace the two M4 screws and wa...

Page 12: ...100 0100 002 AIG 07 05 Printed in U S A 2005 Aigis Mechtronics 1124 Louise Road Winston Salem NC 27107 5450 Tel 336 785 7740 Fax 336 785 7744 Data subject to change without notice...

Reviews: