1
UNPACKING
This electronic equipment should be unpacked and
handled carefully.
Check for the following items:
Quantity
Part Description
1
1/4-20 x 3/8in. BHCS (Button Head Cap
Screw)
1
1/4-20 x 1/2in. BHCS
1
1/4-20 x 5/8in. BHCS
1
1/4-20 x 3/4in. BHCS
1
1/4-20 x 7/8in. BHCS
4
3.2mm (0.125in.) plastic spacer
4
0.4mm (0.016in.) plastic spacer
2
Nylon bushings
1
3/8in. NPT plug
1
Small flex fitting
2
Pull Seals
2
Large flex fitting
3
Cable ties
If an item appears to have been damaged in shipment,
replace it properly in its carton and notify the shipper.
If any items are missing, notify Aigis Mechtronics. The
shipping carton is the safest container in which the unit
may be transported. Save it for possible future use.
2
SERVICE
If the unit ever needs repair service, the customer
should contact Aigis Mechtronics for return
authorization and shipping instructions.
3
CARE AND MAINTENANCE
There are no moving parts in this unit. Regularly
scheduled maintenance will help prolong the
operational life of this unit. Clean the viewing window
as needed with a mild, nonabrasive detergent in water
and a soft cloth.
4
DESCRIPTION
The HS9385 Series of environmental housings are
attractive aluminum enclosures designed for outdoor
CCD camera installations.
4.1
Enclosure Rating
4.1.1
NEMA-3R and IP54
The HS9385 Series housings include a breather hole in
the front face plate. The breather hole prevents the
accumulation of moisture inside the housing when
installed in areas of high humidity. With the breather
hole open, the HS9385 Series housings meet the
enclosure rating requirements of NEMA-3R and IP54.
4.1.2 NEMA-4 and IP65
For installations requiring an enclosure rating of
NEMA-4 or IP65, the breather hole must be plugged
using the pull seal (Part No. 315 2569 001) provided in
the hardware kit. Refer to Final Assembly under
INSTALLATION for proper installation.
SAFETY PRECAUTIONS
CAUTION: TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT REMOVE COVER
(OR BACK). NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
This symbol indicates the presence of
uninsulated “dangerous voltage” within
the product’s enclosure. This may
constitute a risk of electric shock.
The user should consult the operating
and maintenance (servicing)
instructions in the literature
accompanying the appliance.
3
Attention: Installation should be performed by
qualified service personnel only in accordance
with the National Electrical Code or applicable
local codes.
Power Disconnect. Units with or without
ON-OFF switches have power supplied to the unit
whenever the power cord is inserted into the
power source; however, the unit is operational
only when the ON-OFF switch is in the ON
position. The power cord is the main power
disconnect for all units.