9

FIGURE 11  Video Coax Connection

5.10

Lens Wiring

WARNING: Only use the cables  specified
under INSTALLATION, Cable Requirements for
wiring of the lens.

If installing a zoom lens

, insert the lens control cable

with installed flexible fitting in through the fitting on
the right rear of the base assembly. Attach the lens
wiring to the lens mating connector and connect it to
the lens. If mating connector is not available, connect
directly to the lens cable. Pull any excess cable
through the liquid-tight fitting and tighten the flex
fitting to 8.5N-m to 9.0N-m (75in. lb to 80in. lb). This
torque rating is approximately 1 to 1 1/2 turns past
finger-tight, depending on the size of the wire. Failure
to do so will result in water damage to all electronic
parts. Use a tie wrap (included) to provide strain relief
on the lens control cable at the exit point (inside the
unit). See FIGURE 12.

NOTE: See specification on the lens cord for correct
plug connection.

Be sure to securely tighten all fittings to ensure
a liquid-tight seal. Not doing so could damage
the camera, the housing, or both.

FIGURE 12  Lens Control Cable Wiring

If using a pan/tilt with a feed-through cable

, insert

the camera/lens function cable in through the right
fitting at the rear of the cradle. Wire the functions as
described above, or as needed.

5.11

Camera/Lens Orientation

A unique feature of the HS9385 Series housing is 
the ability to rotate the mounting base 360

º

around 

the rail assembly. 

Simply loosen the three M4 screws with a M3 hex
wrench. Rotate the base assembly around the rail
assembly to any position and tighten the M4 screws. 
It is preferable to keep the rail assembly under the
camera, not over it.  See FIGURE 13.

NOTE: Make sure the breather hole is located at the
bottom of the housing. If it is not, remove both front
retaining rings and the face plate. Orient them so the
breather hole is located at the bottom and the gaps in
the retaining rings are centered over the breather hole.
See FIGURE 20.

FIGURE 13  Base Assembly Rotation

5.12

Camera/Lens Adjustment

Before final assembly of the cover over the rest of
housing, verify camera and lens operation. Adjust
camera/lens as necessary. See individual camera
instructions.

CCD Camera

Lens Control Cable

Lens Control

Connectors

CCD Camera

Base Assembly

M4 Screws

Video Coax Cable

BNC Connector

CCD Camera

Small Fitting

Video Coax Cable

BNC Connector

CCD Camera

Small Fitting

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for HS9385 Series

Page 1: ...Screw Bushing Ground Wire Terminal Lug Power Cable Rail Assembly M4 Screws Mounting Holes I N S T A L L A T I O N A N D O P E R A T I N G I N S T R U C T I O N S W W W A I G I S M E C H C O M EXTRA L...

Page 2: ...mpletion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power sour...

Page 3: ...MA 3R and IP54 The HS9385 Series housings include a breather hole in the front face plate The breather hole prevents the accumulation of moisture inside the housing when installed in areas of high hum...

Page 4: ...able Requirements Video Transmission Coaxial Cable Type RG 59 U Runs 1000ft RG 11 U Runs 2000ft Cable Size Outside diameter between 4 6mm and 7 9mm 0 181in and 0 312in Cable Shape Round Shield 93 Brai...

Page 5: ...t the base before installing the camera but it may be mounted anytime during the installation process See FIGURE 3 FIGURE 3 Mounting the Base Assembly 5 6 Camera Lens Installation Place the camera len...

Page 6: ...y tighten all fittings to ensure a liquid tight seal Not doing so could damage the camera the housing or both If a sealant will be used be sure it is a neutral cure type Sealants that release acetic a...

Page 7: ...8 Securing the Ground Wire 4 Connect both the line and neutral wires of the power cord to the terminal block Make sure the line and neutral wires are connected to the correct positions on the termina...

Page 8: ...in to 7 9mm 0 312in See FIGURE 11 2 Attach a BNC connector to the coax and connect it to the camera Pull any excess cable through the liquid tight fitting and tighten the flex fitting to 4 0N m to 4 5...

Page 9: ...Cable Wiring If using a pan tilt with a feed through cable insert the camera lens function cable in through the right fitting at the rear of the cradle Wire the functions as described above or as nee...

Page 10: ...ed from the base assembly do so now see the Disassembly and Mounting section at the beginning of these instructions 2 Obtain a rubber pull seal from the hardware kit Part Number 315 2569 001 An extra...

Page 11: ...ched The safety cable can be routed between the cover and the base See FIGURE 19 FIGURE 19 Replacing the Cover 3 Align the cover holes with the base assembly holes and replace the two M4 screws and wa...

Page 12: ...100 0100 002 AIG 07 05 Printed in U S A 2005 Aigis Mechtronics 1124 Louise Road Winston Salem NC 27107 5450 Tel 336 785 7740 Fax 336 785 7744 Data subject to change without notice...

Reviews: