HYDRO-AIRE SERIES PRESSES
INSTALLATION, OPERATION, AND MAINTENANCE
9
3.5 Turn On Air Supply
A.
Remove the yellow lock out device found on the On-
Off Valve. To turn the air on simply move the gold
colored sleeve downward until it stops. Slide the
sleeve upward to the stop to shut the supply off.
With the supply on, check for air leaks and be sure
all connections you have made are secure and air
tight. If air leaks from inside the "Synchro-Sig"
actuator the connections are incorrect. Correctly
reconnect the tubing, taking note of the tubing
labels.
CAUTION:
ENSURE HANDS ARE CLEAR OF ANY TOOLING BEFORE
TURNING OFF AIR SUPPLY. THE WEIGHT OF A HEAVY
TOOL MAY CAUSE IT TO DROP UNEXPECTEDLY. IF
HEAVY TOOLING IS BEING USED BE SURE TO PLACE A
STOP UNDER TOOLING BEFORE TURNING OFF AIR
SUPPLY
NOTE:
When the press is not in use or being serviced or
maintained, always SHUT OFF the air supply and
replace the lockout device. Secure with a
padlock, etc. to prevent unauthorized use of the
press.
CAUTION:
BEFORE PROCEEDING, MAKE SURE THE TABLE AND
WORK AREA IS CLEAR OF ALL TOOLS, FOREIGN
OBJECTS, AND BODY PARTS.
3.6 Test The Installation
A. Test the "Synchro-Sig" Two Hand Actuator by
simultaneously depressing the levers on the Model
SS-PB or by simultaneously placing a finger in each
sensing "button" on the Model SS-OT. The press
should cycle once, return to the top of the stroke,
and await another signal from the actuator. If the
levers or "buttons" are continuously held down the
press should remain in the down position until one
or both levers or buttons are released.
OFF
ON