Page 7
4
Connections
4.1 Front Panel Connections
A- For each output, the load should be connected to the positive (red) and negative (black)
terminals marked OUTPUT. Both are fully floating and either can be connected to
ground or to a terminal of another output.
B- Remote sense connections to the load, if required, are made from the positive (+) and
negative (-) SENSE terminals. Switch the SENSE switch to REMOTE when remote
sensing is required. Switch back to LOCAL when remote sensing is not in use. See
section 10.2 for more information.
C- The grey terminal marked with an Earth symbol is connected to the chassis and safety
earth ground.
4.2 Rear Panel Connections (MX100QP)
D- The MX100Q has only an AC power connection socket on the rear panel.
The MX100QP also has:
E- Power and sense terminals
F- USB
G- RS232
H- LAN
I- GPIB
All interfaces are fully isolated from the power supply output terminals. USB, RS232 and GPIB
interfaces are connected to chassis ground. The LAN interface is isolated by standard network
transformers.