16
17
8. Analog Inputs
MXG has 8 analog inputs, recorded up to
1000 times per second each.
You can connect:
n
0-5 Volt signals
n
Ratiometric potentiometers
n
Pressure sensors
n
Thermo-resistances
n
K-type thermocouples
Please use the following steps, using the
software RaceStudio3 as explained in
section 10.1:
n
Connect the sensor to the desired input
n
Enable the channel in the Channels table
n
Select the proper sensor type; sensors of
many different types are properly
handled
n
Set the sampling frequency
n
Set the unit of measure.
MXG features two digital outputs in the 22
pins connector.
Each of them can give an output of 1 amp
at 12 volts.
You can configure them in order to turn
them on or off depending upon the value
of the analog or digital inputs, ECU values,
expansion values, GPS information or math
channels.
To every event you can associate an alarm
LED, a message and a digital output.
You can configure them in order to turn
them off when the condition disappears,
when you push a pushbutton, when the
test is finished or when the data are
downloaded after the test.
Please refer to section 10.1.4 in order to see
how to manage the digital outputs.
CHAPTER 8 ANALOG INPUTS
CHAPTER 9 DIGITAL OUTPUT
MXG
9. Digital Output
n
Temperature sensors
n
Pressure sensors
n
Potentiometers
n
Generic sensors
K thermocouples
Thermo-PT100 resistors
Temperature sensors VDO
VDO 40-120 ° C
VDO 50-150 ° C
VDO 60-200 ° C
MSI 0-2 bar
MSI 0-5 bar
MSI 0-10 bar
MSI 0-2000 psi
Distance
Zero-based
Zero Central
0-50 mV
0-500
0-5 V